Item number MODBU-DATA-LOGGE-GATEW

Modbus Data Logger & Gateway with 5x RS-485, 32GB Storage

Modbus TCP/RTU Gateway & Data Logger
2x RS-485 + 3x Isolated RS-485
10/100 Base-TX Ethernet, Auto MDI/MDIX
32GB microSD Storage, CSV Logging
Built-in Web Server File Manager
Modbus RTU Master/Slave, TCP Slave
Baud Rate up to 115200 bps
9600 Registers per AI/AO/DI/DO
Metal Casing, DIN-Rail/Wall Mount
+10 to 48VDC Input, 2W Consumption
-25~75°C (special components required)
97 x 120 x 42 mm

593.62 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Installation DIN-Rail or Wall Mounting
Type 5-Digit 7 Segment LED Display (display system information)
Operating Temperature -25 ~ +75 °C
Status 1 x System, to (display heartbeat)
Ports 10/100 Base-TX, Auto MDI/MDIX2 x 2-wire RS-485 (non-isolated)3 x 2-wire RS-485 (2.5 kV isolation protection)
Input Range +10 ~ +48 VDC
Consumption 2 W
Dimensions (mm) 97 x 120 x 42 (W x L x H)
Storage Temperature -30 ~ +80 °C
Humidity 10 ~ 90 % RH, Non-condensing
Baud Rate 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200 bps
Data Format N81, E81, O81
Protocol Modbus RTU Master/Modbus RTU SlaveModbus/TCP slave, HTTP
Casing Metal
Data Type Boolean, 16-bit Integer, 32-bit Integer and 32-bit Floating
Max. Recording Period per File 1 hr, 2 hr, 6 hr, 12 hr, 24 hr
File Manager Interface Built-in web server
Storage Media 32 GB microSD card
File Format CSV
Time Interval 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min, 1 hr, 6 hr
Max. Records 120 parameters per record
Socket Connections 8 Modbus/TCP
Polling Definition 250 definitions for all RS-485 ports
Shared Memory 9600 registers for each of AI, AO, DI and DO data
Max. Connection 32 slaves for each RS-485 port

Modbus Data Logger and Gateway

This Modbus data logger and gateway connects RS-485 devices to Ethernet networks and records process data locally for later analysis. It functions as both a Modbus TCP/RTU protocol converter and a standalone data recorder, making it ideal for industrial monitoring applications.


5x RS-485 Ports · 10/100 Ethernet · 32GB microSD Logging · Wide Temp Range


Key Features and Benefits

  • Dual Protocol Support - works as Modbus TCP slave and RTU master/slave simultaneously
  • Isolated RS-485 Ports - 3 ports with 2.5kV isolation protect against surges
  • Built-in Data Logging - records up to 120 parameters per record in CSV format
  • Web-based File Manager - access and download log files directly via browser
  • Rugged Metal Enclosure - operates reliably from -25 to +75°C


Typical Applications

The gateway suits industrial environments where reliable data collection and Modbus connectivity are required.

  • Factory automation and process monitoring
  • Building management systems
  • Remote sensor and meter data logging
  • SCADA and PLC network integration


A robust, dual-function solution for combining Modbus connectivity with reliable local data logging.