Item number PROGR-DEVIC-SERVE-RS-7

Programmable Device Server with RS-232/485, 10/100 Ethernet, DIN-Rail

80186-80 MHz compatible CPU
1x RS-232, 4x RS-485 ports
10/100 Base-TX Ethernet RJ-45
Baud rate up to 115200 bps
Max 254 node address
Built-in watchdog timer
DIN-Rail or wall mounting
-25-75C (special components required)
Storage -40 to 80C, 5-90% RH
10-30VDC power input
72 x 35 x 123 mm (WxLxH)

402.00 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU 80186-80 MHz or compatible
Flash 512 KB ; Erase unit is one sector (64 KB) ;100,000 erase/write cycles
Installation DIN-Rail or Wall Mounting
Operating Temperature -25 ~ +75 °C
Watchdog Timer Yes
Status 1 x Power5 x digit 7 Segment
Ports 1 x 5-wire RS-2324 x RS-48510/100 Base-TX, RJ-45 port (Auto-negotiating, auto MDI/MDI-X, LED indicator)
Consumption 2.7 W
Dimensions (mm) 72 mm x 35 mm x 123 mm (W x L x H)
Storage Temperature -40 ~ +80 °C
Humidity 5 ~ 90% RH, Non-condensing
Powered from Terminal Block +10 ~ 30 VDC
Baud Rate 115200 bps Max.
Parity None, Even, Odd, Mark, SpaceNone parity is required when using 8 data bits and 2 stop bits on COM1/COM2.
Data Bit 7, 8: for COM1 and COM25, 6, 7, 8: for COM3 ~ COM5
Stop Bit 1, 2: for COM1 ~ COM5
Casing Plastic
EEPROM 16 KB; Data retention: 40 years; 1,000,000 erase/write cycles.
SRAM 512 KB
Bias Resistor Yes, 1 KΩ
Node Address 254 (max.)

Serial Device Server

This serial device server connects RS-232 and RS-485 serial devices to Ethernet networks, enabling remote monitoring and control in industrial environments. It is designed for reliable operation in harsh conditions and integrates easily into existing automation systems.


1x RS-232 / 4x RS-485 · 10/100 Base-TX Ethernet · DIN-Rail Mounting · -25 to 75C Operation


Key Features and Benefits

  • Multiple Serial Ports - connect several RS-232 and RS-485 devices simultaneously
  • 10/100 Base-TX Ethernet - fast and reliable network connectivity
  • Wide Operating Temperature - runs reliably from -25 to +75C
  • Watchdog Timer - automatic recovery from system faults
  • Flexible Mounting - DIN-rail or wall installation options


Typical Applications

The device server fits seamlessly into industrial and building automation setups where serial equipment needs network access.

  • Industrial automation networks
  • Remote monitoring and control systems
  • Building management systems
  • Factory floor device integration


A robust and flexible solution for bringing serial devices onto the network.