Item number PROGR-DEVIC-SERVE-4X

Programmable Device Server with 4x DI, 4x DO, 2x RS-232/485

10/100 Base-TX Ethernet RJ-45
2x RS-232/RS-485 serial ports
4 x Digital Input (Dry Contact)
4 x Digital Output (Open Collector)
Auto MDI/MDI-X, auto-negotiating
Baud rate up to 115200 bps
Watchdog timer
DIN-rail or wall mounting
10-30VDC power input, 2.0W
72 x 35 x 123 mm (WxLxH)
-25~+75C (special components required)
5-90% RH non-condensing

336.34 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU 80186-80 MHz or compatible
Flash 512 KB ; Erase unit is one sector (64 KB) ;100,000 erase/write cycles
Installation DIN-Rail or Wall Mounting
Type Dry ContactOpen Collector
Operating Temperature -25 ~ +75 °C
Watchdog Timer Yes
Status 1 x Power
Ports 2 x 5-wire RS-2321 x RS-48510/100 Base-TX, RJ-45 port (Auto-negotiating, auto MDI/MDI-X, LED indicator)
Consumption 2.0 W
Dimensions (mm) 72 mm x 35 mm x 123 mm (W x L x H)
Storage Temperature -40 ~ +80 °C
Humidity 5 ~ 90% RH, Non-condensing
Channels 4
Powered from Terminal Block +10 ~ 30 VDC
Sink/Source (NPN/PNP) Source, Common GroundSink (NPN)
ON Voltage Level +3.5 ~ +30 V
OFF Voltage Level +1 V max.
Load Voltage 30 VDC, max.
Load Current 100 mA, max.
Baud Rate 115200 bps Max.
Parity None, Even, Odd, Mark, SpaceNone parity is required when using 8 data bits and 2 stop bits on COM1/COM2.
Data Bit 7, 8: for COM1 and COM25, 6, 7, 8: for COM3
Stop Bit 1, 2: for COM1 ~ COM3
Casing Plastic
EEPROM 16 KB; Data retention: 40 years; 1,000,000 erase/write cycles.
SRAM 512 KB
Bias Resistor Yes, 1 KΩ
Node Address 254 (max.)

Programmable Device Server

The Programmable Device Server is an industrial communication gateway that connects serial devices, digital inputs and digital outputs to an Ethernet network. It is designed for reliable data acquisition and control in demanding automation environments.


4x Digital Input · 4x Digital Output · 2x RS-232/RS-485 · 10/100 Base-TX Ethernet


Key Features

  • Dual Serial Ports - two RS-232/RS-485 interfaces for connecting legacy serial equipment
  • Digital I/O - 4 dry contact inputs and 4 open collector outputs for monitoring and control
  • Auto-negotiating Ethernet - 10/100 Base-TX port with auto MDI/MDI-X for flexible cabling
  • Wide Operating Temperature - rated from -25C to +75C for harsh industrial environments
  • Watchdog Timer - built-in watchdog ensures continuous, reliable operation


Typical Applications

The device server suits a wide range of industrial monitoring and control tasks where serial equipment must be integrated into an Ethernet network.

  • Factory automation and machine monitoring
  • Remote I/O control for SCADA systems
  • Integration of legacy serial devices into IP networks
  • DIN-rail mounted control panels


A robust and flexible device server for connecting serial and I/O devices to Ethernet networks.