BACnet, DNP3 and M-Bus

BACnet, DNP3 and M-Bus

This category gathers gateways that translate between building automation and industrial protocols. BACnet/IP is used in ventilation and heating systems. DNP3 and M-Bus are used in utility and metering data. The gateway lets data from these systems be read by a Modbus-based controller or a SCADA system without separate integrations.

Choose based on which protocols need to be connected on each side. Check whether the device works as master or slave. Look at the number of supported stations or M-Bus slaves. Check physical interfaces such as RS-485 and RJ45 and whether PoE is needed. Mounting is typically DIN-rail for use in a cabinet.

BACnet, DNP3 and M-Bus
There are 13 products.
IEC 61850 MMS Gateway with Modbus TCP Client, DIN-Rail

IEC 61850 MMS server, Modbus TCP client
Cortex-A8 1GHz CPU
512MB DDR3 RAM
2 x RJ45 10/100/1000 Ethernet
2 x RS-232, 2 x RS-485 ports
2 x USB 2.0 Host ports
VGA output (Analog RGB)
OS: Linux Kernel 3.2.14
12-48VDC power input
35 x 167 x 119 mm (WxLxH)
-25~+75C (special components required)
DIN-Rail or wall mount

Call +45 56 66 20 20 for price
Item numberIEC-61850-MMS-GATEW
On the way in
DNP3 to Modbus TCP Protocol Gateway, Dual RJ45, RS-232/485

DNP3 Master, Modbus TCP Server
Cortex-A8 1GHz CPU
512MB DDR3 SDRAM
2x RJ45 Gigabit Ethernet
2x RS-232, 2x RS-485
2x USB 2.0 Host
Dual Watchdog Timer
Real Time Clock
Linux Kernel 3.2.14
-25~75C (special components required)
12-48VDC
35 x 167 x 119 mm

Call +45 56 66 20 20 for price
Item numberDNP3-MODBU-TCP-PROTO
On the way in
DNP3 Slave to Modbus TCP Client Gateway, Cortex-A8, DIN-Rail, -25~75°C

DNP3 slave protocol, RS-485/TCP/UDP
Modbus TCP client, max 32 servers
Cortex-A8 1GHz CPU, 512MB DDR3
Dual Watchdog Timer, RTC included
2 x RJ45 10/100/1000 Base-TX
2 x RS-232, 2 x RS-485 ports
2 x USB 2.0 Host, VGA output
Metal casing, DIN-rail mount
Linux Kernel 3.2.14
12-48VDC, 4.8W consumption
35 x 167 x 119 mm (WxLxH)
-25~75°C (special components required)

Call +45 56 66 20 20 for price
Item numberDNP3-SLAVE-MODBU-TCP
On the way in
Modbus RTU to TCP Gateway with PoE, 2x RJ45, RS-422/485

32-bit MCU
2x 10/100 RJ45, Auto-MDI/MDIX
PoE IEEE 802.3af Class 2
LAN bypass function
Modbus TCP/UDP/TCP-TLS, OPC UA
HTTP/HTTPS, IPv4/IPv6, SNTP
1x RS-422/485, isolated
Baud rate up to 115200 bps
Bias resistor 1 K Ohm
Metal casing, DIN-rail mount
-25 to +75C (special components required)
12-48VDC, PoE 802.3af

444.88 €
Item numberMODBU-RTU-TCP-GATEW
On the way in
BACnet/IP to Modbus RTU Gateway, DIN-Rail, 1x RJ45, 10-30VDC

BACnet/IP to Modbus RTU Master gateway
Supports up to 32 Modbus stations
1 x RJ45 10/100Base-TX Ethernet
Terminal block D+, D-, TxD, RxD, GND
Objects: AI, AO, AV, BI, BO, BV, MSI, MSO, MSV
Converts 180 DI, DO, AI and AO points
BIBBs: DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B
Metal casing, DIN-Rail mount
10-30VDC, 5W @ 24VDC
33 x 120 x 116 mm
-25 to 75C (special components required)
Humidity 10-90% RH, non-condensing

624.44 €
Item numberBACNE-IP-MODBU-RTU
On the way in
3-Port RS-422/485 to Ethernet Gateway with PoE, Modbus TCP/UDP, OPC UA

3 x RS-422/485 Isolated Ports
2 x 10/100 Base-TX RJ-45, LAN Bypass
PoE IEEE 802.3af, Class 2
Modbus TCP, TCP/TLS, UDP, OPC UA
HTTP/HTTPS, SNTP, IPv4, IPv6
32-bit MCU
Baud Rate up to 115200 bps
Bias Resistor 1 KOhm
Metal Casing, DIN-Rail Mount
+12-48VDC or PoE Powered
106 x 33 x 119 mm
25 to 75C (special components required)

596.30 €
Item numberPORT-RS-422-485-2
On the way in
BACnet/IP I/O Module, 4AI/2AO/4DI/4DO, DIN-Rail

BACnet/IP Server, 1x RJ-45 10/100
4x Analog Input, 16-bit, +/-10V
2x Analog Output, 12-bit, 0-10V
4x Digital Input, Dry Contact
4x Digital Output, Open Collector
Objects: 1 Device, 4 AI, 2 AO, 4 BI, 4 BO
Watchdog Timer and ID/Password Security
Power, Ethernet and BIP Status LEDs
Metal Casing, DIN-Rail Mounting
10-30VDC, 3.6W
33 x 120 x 106 mm
-25 to +75C (special components required)

326.96 €
Item numberBACNE-IP-MODUL-4AI
On the way in
Modbus Gateway with 2x RS-422/485, PoE, LAN Bypass

2 x RS-422/485 ports, isolated
2 x 10/100 RJ-45, PoE 802.3af
LAN bypass function
Modbus TCP/UDP, Modbus TCP/TLS
OPC UA, SNTP, HTTP/HTTPS
IPv4, IPv6 support
Baud rate up to 115200 bps
Bias resistor 1 KOhm
32-bit MCU
12-48VDC or PoE powered
106 x 33 x 119 mm
-25 to 75C (special components required)

533.32 €
Item numberMODBU-GATEW-2X-RS
On the way in
M-Bus to Modbus TCP Gateway with RS-232, up to 100 Slaves

RJ-45 10/100Base-T(X) Ethernet port
Modbus TCP protocol support
RS-232 port, non-isolated
M-Bus port, up to 100 slaves
Baud rate 300-115200 bps (RS-232)
Baud rate 300-2400 bps (M-Bus)
Isolation 3750 Vrms photo-couple
Short-circuit protection
Wall mounting
24VDC power input
102 x 123 x 40 mm
-25~75C (special components required)

443.54 €
Item numberBUS-MODBU-TCP-GATEW
On the way in
BACnet/IP to Modbus TCP/RTU Gateway, DIN-Rail, 10/100Base-TX

BACnet/IP Client to Modbus TCP/RTU
Up to 10 BACnet/IP Servers
Up to 9000 BACnet object values
Objects: AI, AO, AV, BI, BO, BV, MSI, MSO, MSV
BIBBs: DS-RP-A, DS-RPM-A, DS-WP-A, DS-WPM-A
1 x RJ-45 10/100Base-TX
Modbus TCP up to 2 connections
Metal casing, DIN-Rail mount
10-30VDC, 5W @ 24VDC
-25 to 75C (special components required)
33 x 120 x 116 mm
10-90% RH non-condensing

624.44 €
Item numberBACNE-IP-MODBU-TCP
On the way in
BACnet/IP to Modbus TCP Gateway, 32 Stations, DIN-Rail

Modbus TCP Client, up to 32 stations
BACnet objects: AI, AO, AV, BI, BO, BV
MSI, MSO, MSV supported
Converts 180 DI, DO, AI and AO points
BIBBs: DS-RP-B, DS-RPM-B, DS-WP-B
DS-WPM-B, DM-DDB-B, DM-DCC-B, DM-RD-B
1 x RJ-45, 10/100Base-TX
Metal casing, DIN-Rail mount
10-30VDC, 5W @ 24VDC
33 x 120 x 116 mm
-25 to 75C (special components required)
Humidity 10-90% RH, non-condensing

624.44 €
Item numberBACNE-IP-MODBU-TCP-2
On the way in
M-Bus Master/Slave Converter, DIN-Rail, -25 to 75°C

1 Master Port, 1 Slave Port
Auto-adjust Baud Rate
Isolation 3750 Vrms photo-couple
Short-circuit Protection
DIN-Rail Installation
Consumption 1.6-9.7W @ 24VDC
Storage Temp -30 to 80°C
Humidity 10-90% RH non-condensing
-25-75°C (special components required)
Supply: 24VDC
Dimensions: 25 x 116 x 120 mm

257.28 €
Item numberBUS-MASTE-SLAVE-CONVE
On the way in
BACnet MS/TP to Modbus TCP Gateway, DIN-Rail, 32 Connections

BACnet MS/TP Master to Modbus TCP
Max. 32 connections
Objects: AI, AO, AV, BI, BO, BV, MSI, MSO, MSV
BIBBs: DS-RP-A, DS-RPM-A, DS-WP-A, DS-WPM-A
Baud rate: 9600-76800
Built-in 120 ohm terminator resistor
Isolation: 3kV DC / 2500 Vrms
Metal casing, DIN-Rail mount
5W @ 24VDC
33 x 120 x 116 mm
-25 to +75C (special components required)
Humidity 10-90% RH non-condensing

624.44 €
Item numberBACNE-MS-TP-MODBU
On the way in
Showing 1-13 of 13 item(s)