Item number DNP3-SLAVE-MODBU-TCP

DNP3 Slave to Modbus TCP Client Gateway, Cortex-A8, DIN-Rail, -25~75°C

DNP3 slave protocol, RS-485/TCP/UDP
Modbus TCP client, max 32 servers
Cortex-A8 1GHz CPU, 512MB DDR3
Dual Watchdog Timer, RTC included
2 x RJ45 10/100/1000 Base-TX
2 x RS-232, 2 x RS-485 ports
2 x USB 2.0 Host, VGA output
Metal casing, DIN-rail mount
Linux Kernel 3.2.14
12-48VDC, 4.8W consumption
35 x 167 x 119 mm (WxLxH)
-25~75°C (special components required)

Call +45 56 66 20 20 for price
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU Cortex-A8, 1 GHz
Installation DIN-Rail or Wall Mounting (optional)
Operating Temperature -25 ~ +75 °C
OS Linux Kernel 3.2.14
Service SFTP server
System Memory 512 MB DDR3 SDRAM
Real Time Clock Yes (Provide seconds, minutes, hours, day of week, month, year)
Watchdog Timer Yes, Dual Watchdog Timer
Signal VGA (Analog RGB)
Status 1 x PWR(Power) 1 x RUN(Running)1 x L11 x L21 x L3
Ports 2 x RJ-45, 10/100/1000 Base-TX1 x RS-232 (Console, Non-isolated)1 x RS-232, Non-isolated1 x RS-485, Non-isolated1 x RS-485 (2500 VDC, Isolated)2
Input Range +12 VDC ~ +48 VDC
Consumption 4.8 W
Dimensions (mm) 35 x 167 x 119 (W x L x H)
Storage Temperature -40 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
Specification USB 2.0 (Host)
Protocol DNP3 slave:• Data Group:1, 10, 11, 30, 40, 41• Connection: RS-485 / TCP / UDP• Data Points: DI: 8192 DO: 8192 AI: 2048 AO: 2048Modbus TCP client:• Function:1, 2, 3, 4 , 15, 16• Connection: Max. 32 Modbus TCP servers
Casing Metal

DNP3 to Modbus TCP Protocol Gateway

This protocol gateway converts DNP3 slave communication to Modbus TCP client requests, allowing seamless integration between legacy DNP3 devices and modern Modbus TCP based control systems. It is built for continuous operation in demanding industrial environments.


DNP3 Slave & Modbus TCP Client · Cortex-A8 1GHz CPU · Dual RS-485/RS-232 · -25 to +75°C Operation


Reliable Protocol Conversion Features

  • DNP3 Slave Support - handles up to 8192 digital and 2048 analog data points
  • Modbus TCP Client - connects to as many as 32 Modbus TCP servers simultaneously
  • Dual Watchdog Timer - ensures automatic recovery from software or hardware faults
  • Real Time Clock - keeps accurate time stamping for logged events
  • Wide Operating Range - runs reliably from -25 to +75°C in a rugged metal casing


Typical Installation Areas

The gateway suits environments where DNP3 based SCADA systems need to communicate with Modbus TCP equipment.

  • Power distribution and substations
  • Water and wastewater treatment plants
  • Remote monitoring and telemetry systems
  • Industrial automation networks


A robust and flexible choice for connecting DNP3 and Modbus TCP infrastructures reliably.