Item number DNP3-MODBU-TCP-PROTO

DNP3 to Modbus TCP Protocol Gateway, Dual RJ45, RS-232/485

DNP3 Master, Modbus TCP Server
Cortex-A8 1GHz CPU
512MB DDR3 SDRAM
2x RJ45 Gigabit Ethernet
2x RS-232, 2x RS-485
2x USB 2.0 Host
Dual Watchdog Timer
Real Time Clock
Linux Kernel 3.2.14
-25~75C (special components required)
12-48VDC
35 x 167 x 119 mm

Call +45 56 66 20 20 for price
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU Cortex-A8, 1 GHz
Installation DIN-Rail or Wall Mounting (optional)
Operating Temperature -25 ~ +75 °C
OS Linux Kernel 3.2.14
Service SFTP server
System Memory 512 MB DDR3 SDRAM
Real Time Clock Yes (Provide seconds, minutes, hours, day of week, month, year)
Watchdog Timer Yes, Dual Watchdog Timer
Signal VGA (Analog RGB)
Status 1 x PWR(Power) 1 x RUN(Running)1 x L11 x L21 x L3
Ports 22 x RJ-45, 10/100/1000 Base-TX1 x RS-232 (Console, Non-isolated)1 x RS-232, Non-isolated1 x RS-485, Non-isolated1 x RS-485 (2500 VDC, Isolated)
Input Range +12 VDC ~ +48 VDC
Consumption 4.8 W
Dimensions (mm) 35 x 167 x 119 (W x L x H)
Storage Temperature -40 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
Specification USB 2.0 (Host)
Protocol Modbus TCP server:• Function:1, 2, 3, 4, 15, 16• connection:Max. 16 Modbus TCP clientsDNP3 master:• connection:Max. 32 DNP3 Outstations• Data Group:1, 10, 12, 20, 30, 40, 41• Data Points: DI: 8192 DO: 8192 Count: 2048 AI: 2048 AO: 2048
Casing Metal

DNP3 to Modbus TCP Protocol Gateway

This protocol gateway converts DNP3 master communication to Modbus TCP server data, allowing seamless integration between SCADA systems and Modbus-based devices. It is designed for demanding industrial environments where reliable data exchange is critical.


DNP3 Master · Modbus TCP Server · Dual Gigabit Ethernet · -25 to 75°C


Key Features

  • DNP3 to Modbus TCP Conversion - enables interoperability between different protocol networks
  • Dual Gigabit Ethernet Ports - supports redundant network connections for high availability
  • Multiple Serial Interfaces - RS-232 and RS-485 ports for connecting legacy serial devices
  • Dual Watchdog Timer - ensures continuous operation and automatic recovery from faults
  • Wide Operating Temperature Range - reliable performance from -25°C to +75°C in harsh conditions


Typical Applications

The gateway is well suited for critical infrastructure and industrial control systems that require robust protocol translation.

  • Power grid substations
  • Water and wastewater treatment
  • Oil and gas facilities
  • Industrial automation networks


A rugged and reliable choice for integrating DNP3 and Modbus TCP systems in demanding industrial environments.