Item number BACNE-IP-MODBU-TCP

BACnet/IP to Modbus TCP/RTU Gateway, DIN-Rail, 10/100Base-TX

BACnet/IP Client to Modbus TCP/RTU
Up to 10 BACnet/IP Servers
Up to 9000 BACnet object values
Objects: AI, AO, AV, BI, BO, BV, MSI, MSO, MSV
BIBBs: DS-RP-A, DS-RPM-A, DS-WP-A, DS-WPM-A
1 x RJ-45 10/100Base-TX
Modbus TCP up to 2 connections
Metal casing, DIN-Rail mount
10-30VDC, 5W @ 24VDC
-25 to 75C (special components required)
33 x 120 x 116 mm
10-90% RH non-condensing

624.44 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Installation DIN-Rail
Operating Temperature 25 ~ +75 °C
Status Power (1), BACnet/IP Status (1), BACnet/IP Net(1), Modbus TCP TxD/RxD/Link (3)Ethernet LED Ethernet Status (RJ-45) (2)
Ports 1 x RJ-45, 10/100Base-TX
Input Range +10 ~ +30 VDC
Consumption 5 W @ 24 VDC
Dimensions (mm) 33 x 120 x 116
Storage Temperature 30 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
Protocol BACnet/IP Client (Supports up to 10 BACnet/IP Servers)Modbus TCP Server and Modbus RTU Slave(up to 2 TCP connections)
Casing Metal
Objects AI, AO, AV, BI, BO, BV, MSI, MSO, MSV(Supports up to 9000 BACnet objects' present value)
BIBBs DS-RP-A, DS-RPM-A, DS-WP-A, DS-WPM-A, DM-DDB-A, DM-DOB-A, DM-DCC-A, DM-RD-A

BACnet/IP to Modbus Gateway

This gateway connects BACnet/IP networks with Modbus TCP and RTU devices, enabling integration between building automation systems and industrial control equipment. It operates as a BACnet/IP client while communicating with up to two Modbus TCP connections. It is well suited for DIN-rail mounting in cabinets and technical rooms.


BACnet/IP Client · Up to 10 BACnet/IP Servers · Up to 9000 object values · DIN-Rail mounting


Features that simplify integration

  • Protocol conversion -translates between BACnet/IP and Modbus TCP/RTU without extra software
  • Large object capacity -supports up to 9000 BACnet object present values
  • Flexible server connectivity -communicates with up to 10 BACnet/IP servers simultaneously
  • Rugged metal casing -withstands industrial environments and wide temperatures
  • Status LEDs -provide quick overview of power, network, and protocol status


Use in building and industrial automation

The gateway suits installations where BACnet-based systems need to communicate with Modbus equipment.

  • HVAC system integration
  • Linking BMS with industrial PLCs
  • Monitoring of energy meters
  • Control of building technical installations


A reliable solution for bridging BACnet and Modbus in industrial and building automation installations.