Item number PROGR-DEVIC-SERVE-6X-2

Programmable Device Server, 6x DI, 7x DO, RS-232/485 Ethernet

80186-80MHz CPU or compatible
6 x Digital Input (Wet Contact)
7 x Digital Output (Open Collector)
1 x RS-232, 1 x RS-485
10/100 Base-TX Ethernet RJ-45
Watchdog Timer
Metal casing, wall mounting
-25~+75C (special components required)
10-30VDC power supply
102 x 29 x 125 mm (WxLxH)

2,000.00 kr
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU 80186-80 MHz or compatible
Flash 512 KB ; Erase unit is one sector (64 KB); 100,000 erase/write cycles
Installation Wall mounting
Type Open CollectorWet Contact
Operating Temperature -25 ~ +75 °C
Watchdog Timer Yes
Status 1 x Power5 x digit 7 Segment
Ports 1 x 5-wire RS-2321 x RS-48510/100 Base-TX, RJ-45 port (Auto-negotiating, auto MDI/MDI-X, LED indicator)
Consumption 2.7 W
Dimensions (mm) 102 mm x 29 mm x 125 mm (W x L x H)
Storage Temperature -40 ~ +80 °C
Humidity 5 ~ 90% RH, Non-condensing
Channels 76
Powered from Terminal Block +10 ~ 30 VDC
Sink/Source (NPN/PNP) Sink (NPN)Source, Common Ground
ON Voltage Level +3.5 ~ +30 V
OFF Voltage Level +1 V max.
Load Voltage 30 VDC, max.
Load Current 100 mA, max.
Baud Rate 115200 bps Max.
Parity None, Even, Odd, Mark, SpaceNone parity is required when using 8 data bits and 2 stop bits on COM1/COM2.
Data Bit 7, 8: for COM1 and COM2
Stop Bit 1, 2: for COM1 ~ COM2
Casing Metal
EEPROM 16 KB; Data retention: 40 years; 1,000,000 erase/write cycles.
SRAM 512 KB
Bias Resistor Yes, 1 KΩ
Node Address 254 (max.)

Programmable Device Server

This programmable device server connects serial devices to Ethernet networks, converting RS-232 and RS-485 signals for industrial automation systems. It combines digital I/O channels with serial communication to control and monitor field devices remotely.


6x Digital Input · 7x Digital Output · RS-232/RS-485 · -25 to +75C


Key Features

  • Wide Temperature Range - operates reliably from -25C to +75C
  • Dual Serial Ports - RS-232 and RS-485 for flexible device connection
  • Digital I/O - 6 wet contact inputs and 7 open collector outputs
  • Ethernet Connectivity - 10/100 Base-TX with auto MDI/MDI-X
  • Rugged Metal Casing - built for demanding industrial environments


Typical Applications

The device server suits industrial environments where remote monitoring and serial-to-Ethernet conversion are required.

  • Factory automation and process control
  • Remote I/O monitoring systems
  • Legacy serial device integration
  • Building and infrastructure monitoring


A robust choice for connecting serial and digital I/O devices to Ethernet networks in demanding industrial settings.