Item number HART-RS-232-422-3

HART to RS-232/422/485 Gateway, Modbus RTU/ASCII, 1-Port

1-port HART gateway
RS-232 (3-wire) / RS-422 / RS-485
Modbus RTU / Modbus ASCII protocol
Supports 2-wire or 4-wire HART devices
Point to point or multi-drop topology
Up to 15 HART devices
Burst mode supported
Baud rate up to 115200 bps
10-30VDC power input
72 x 35 x 121 mm (W x L x H)
-40 to +75C operating temp
DIN-rail or wall mounting

463.64 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Data Only Digital Data
Installation DIN-Rail or Wall Mounting (Horizontal)
Isolation UL1577 Spec.
Operating Temperature 40 ~ +75 °C
Ports 1RS-232(3 wires) / RS-422 / RS-485
Input Range Unregulated +10 ~ +30 VDC
Consumption 1 W
Dimensions (mm) 72 x 35 x 121 (W x L x H) Detail
Storage Temperature 40 ~ +80 °C
Humidity 10% ~ 90% RH, non-condensing
Reverse Polarity Protection Power reverse polarity protection, Over-voltage brown-out protection
Baud Rate 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Protocol 2-pin screwed terminal blockModbus RTU / Modbus ASCII
Device 2-wired or 4-wired HART devices
Topology Point to Point or Multi-Drop
Frame Type Short and Long Frame
Burst Mode Supported
Max. HART Device 15
Loop Resistor 250 Ω (1/4W) by Jumper
Loop Power No

HART Gateway

This HART gateway converts between the HART protocol and serial communication, allowing 2-wire or 4-wire HART devices to be easily integrated into existing Modbus networks. It is well suited for industrial process control applications requiring reliable communication with field instruments.


RS-232/422/485 · Modbus RTU/ASCII · Up to 15 HART devices · 10-30VDC


Features that make the difference

  • Flexible serial ports - supports RS-232 (3-wire), RS-422, and RS-485 for wide compatibility
  • Multi-drop topology - connects up to 15 HART devices on the same loop
  • Burst mode - enables faster data updates from field devices
  • Robust protection - reverse polarity and over-voltage protection ensure stable operation
  • Wide operating temperature - reliable operation from -40°C to +75°C


Application areas

The gateway is designed for industrial environments where HART instruments need to communicate with a higher-level Modbus system.

  • Process monitoring in oil and gas industry
  • Integration of field instruments into SCADA systems
  • Water and wastewater treatment plants
  • Automation projects with existing HART sensors


A reliable and flexible solution for bridging HART instruments and Modbus-based control systems.