Item number PORT-HART-USB-GATEW

2-Port HART to USB Gateway with Isolated Loop Power

HART Gateway via USB Type-C
2 Ports, Point-to-Point/Multi-Drop
Protocol: HART, Modbus RTU/ASCII
Loop Power +27VDC, max 15 devices
Isolation per UL1577 spec
Reverse polarity protection
Baud Rate 1200-115200 bps
Windows XP/7/8/10/11 (32/64-bit)
Input +10-30VDC
Dimensions 31 x 134 x 143 mm
-25-75°C (special components required)

684.74 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Data Only Digital Data
Installation Slot
Isolation UL1577 Spec.
Connector USB Type C
Driver Windows XP / 7 / 8 / 10 / 11 (32/64 bit)
Operating Temperature -25 ~ +75 °C
Status PWR / RUN / E0 / E1
Ports Backplane (Virtual COM)2
Input Range Unregulated +10 ~ +30 VDC
Consumption Max. 2.3 W (Point to Point HART wiring)Max. 4.5 W (Multi-drop HART wiring)
Dimensions (mm) 31mm x 134mm x 143mm (W x L x H)
Storage Temperature -30 ~ +80 °C
Humidity 10% ~ 90% RH, non-condensing
Specification USB 1.1 and 2.0 standard
Reverse Polarity Protection Power reverse polarity protection, Over-voltage brown-out protection
Baud Rate 1200 ~ 115200 bps
Data Format N/O/E(parity), 8(data bit), 1/2(stop bit)
Protocol Modbus RTU / Modbus ASCIIHART
Virtual COM Parameter 1200 ~ 115200 bps, N/O/E(parity), 8(data bit), 1/2(stop bit)
Device 2-wired or 4-wired HART devices
Topology Point to Point or Multi-Drop
Frame Type Short and Long Frame
Burst Mode Supported
Max. HART Device 15
Loop Resistor 250 Ω resistor by Dip-Switch
Loop Power Yes (module provides +27VDC)

HART Gateway

This HART gateway converts USB to HART signals, enabling direct communication with 2-wired or 4-wired HART devices. It is used to configure, calibrate and monitor HART instruments from a PC without extra wiring.


2 HART Ports · USB Type-C · Loop Power +27VDC · Isolated per UL1577


Key Features

  • USB Type-C Connection - simple plug and play link to any PC
  • Loop Power - integrated +27VDC supply for HART devices
  • Galvanic Isolation - protects the PC per UL1577 standard
  • Multi-Drop Support - up to 15 HART devices on one loop
  • Reverse Polarity Protection - safeguards against wiring errors


Typical Applications

The gateway fits into process automation environments where HART instruments need to be accessed from standard PCs.

  • Field instrument configuration and calibration
  • Process monitoring in industrial plants
  • Maintenance of pressure, flow and temperature transmitters
  • Retrofitting HART communication to legacy systems


A reliable and isolated USB-to-HART link for demanding industrial environments.