Item number HART-MODBU-GATEW-RS

HART to Modbus Gateway, RS-232/422/485, 1-Port HART Interface

1 x HART port, 2/4-wire devices
Modbus RTU / Modbus ASCII
RS-232(3-wire) / RS-422 / RS-485
Point to Point or Multi-Drop
Max. 15 HART devices
Burst mode supported
Baud rate up to 115200
Loop resistor 250 Ohm via jumper
Isolation per UL1577
10-30VDC, 1W consumption
72 x 35 x 121 mm
-25 to 75C (special components required)

443.54 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Data Only Digital Data
Installation DIN-Rail or Wall Mounting (Horizontal)
Isolation UL1577 Spec.
Operating Temperature 25 ~ +75 °C
Ports 1RS-232(3 wires) / RS-422 / RS-485
Input Range Unregulated +10 ~ +30 VDC
Consumption 1 W
Dimensions (mm) 72 x 35 x 121 (W x L x H) Detail
Storage Temperature 30 ~ +80 °C
Humidity 10% ~ 90% RH, non-condensing
Reverse Polarity Protection Power reverse polarity protection, Over-voltage brown-out protection
Baud Rate 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Protocol 2-pin screwed terminal blockModbus RTU / Modbus ASCII
Device 2-wired or 4-wired HART devices
Topology Point to Point or Multi-Drop
Frame Type Short and Long Frame
Burst Mode Supported
Max. HART Device 15
Loop Resistor 250 Ω (1/4W) by Jumper
Loop Power No

HART Gateway

This HART Gateway converts data from HART instruments into Modbus RTU or Modbus ASCII, allowing 2-wire and 4-wire HART devices to be easily integrated into existing automation systems. The device acts as a central link between field instruments and a supervisory control system via serial communication.


1 x HART port · Modbus RTU/ASCII · RS-232/422/485 · Up to 15 HART devices


Features that ensure reliable operation

  • Flexible topology -supports both Point to Point and Multi-Drop setups
  • Burst mode -enables faster data exchange from HART devices
  • Galvanic isolation -protects equipment according to the UL1577 specification
  • Robust protection -built-in over-voltage and reverse polarity protection
  • Adjustable loop resistor -250 Ohm loop resistor selectable via jumper


Application in industrial environments

The gateway is well suited for monitoring and controlling field instruments in process industries where HART communication needs to be integrated with a Modbus-based system.

  • Process monitoring in oil and gas plants
  • Integration of HART sensors into SCADA systems
  • Maintenance and calibration of field instruments
  • Automation in water treatment facilities


A compact and reliable solution for bridging HART instruments and Modbus networks.