Item number CANOP-PROFI-DP-V0

CANopen to PROFIBUS DP-V0 Gateway, DIN-Rail, -25 to +75°C

CANopen DS-301 to PROFIBUS DP-V0
NXP SJA1000T CAN controller, 16MHz
Profichip VPC3+C PROFIBUS controller
CAN baud rate up to 1Mbps
PROFIBUS baud rate up to 12Mbps
Isolated: CAN 1000VDC, PROFIBUS 3000VDC
RS-232 port for firmware update
Built-in watchdog timer
PWR, RUN, ERR status LEDs
DIN-rail mount, 2.5W consumption
72 x 33 x 119 mm
-25 to +75C operating temperature

479.72 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU 80186, 80 MHz or compatible
Controller NXP SJA1000T with 16 MHz clockProfichip VPC3+C
Flash 512 KB
Installation DIN-Rail
Isolation 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple3000 VDC for DC-to-DC, 2500 Vrms for bus-to-logic
Transceiver ADI ADM2486
Operating Temperature -25 ~ +75℃
Watchdog Timer Watchdog ICCPU built-in
Status PWR LED, RUN LED, ERR LED
Ports RS-232 (For updating firmware and configuration)3-pin screwed terminal block (RxD, TxD, GND)
Consumption 2.5 W
Dimensions (mm) 72 x 33 x 119 (W x L x H)
Storage Temperature -30 ~ +85 ℃
Humidity 5 ~ 95% RH, non-condensing
Specification CANopen DS-301 ver4.02
Baud Rate 9.6 k, 19.2 k, 45.45 k, 93.75 k, 187.5 k, 500 k, 1.5 M, 3 M, 6 M, 12 M1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Parity None, Even, Odd
Data Bit 7, 8
Stop Bit 1, 2
Protocol DP-V0
EEPROM 16 KB
SRAM 512 KB

CANopen to PROFIBUS Gateway

This gateway connects CANopen networks to PROFIBUS DP-V0 systems, enabling seamless data exchange between the two fieldbus protocols. It is designed for industrial automation environments where reliable, isolated communication between controllers and devices is required.


CANopen DS-301 v4.02 · PROFIBUS DP-V0 · DIN-Rail Mounting · -25 to +75°C


Reliable Fieldbus Communication

  • Dual Isolation - protects CAN and PROFIBUS sides from electrical interference
  • NXP SJA1000T Controller - stable CAN bus communication at up to 1 Mbps
  • Profichip VPC3+C Controller - handles PROFIBUS DP-V0 traffic up to 12 Mbps
  • Built-in Watchdog - automatically resets the device in case of a fault
  • Status LEDs - PWR, RUN and ERR indicators for quick diagnostics


Where It Is Used

The gateway fits into industrial control systems that combine CANopen and PROFIBUS equipment on the same production line.

  • Factory automation
  • Machine building
  • Process control systems
  • DIN-rail control cabinets


A dependable choice for bridging CANopen and PROFIBUS networks in demanding industrial environments.