Item number ETHER-MODUL-DIGIT-INPUT-24

Ethernet I/O Module with 2 x Digital Input, 2 x Open Collector Output, Modbus TCP/MQTT

2 x Digital Input, Wet Contact
ON +10 to +50VDC, OFF +4VDC max
2 x Open Collector Output
Load 5-30VDC, 100mA/channel
Modbus TCP, Modbus UDP, MQTT
1 x RJ45 10/100 Base-Tx
Built-in Web Server
Password and IP Filter
Isolation 3750 Vrms
12-48VDC, 0.9W
52 x 95 x 27 mm
25 to 75C (special components required)

116.58 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU 32-bit MCU
Installation DIN-Rail Mounting
Isolation 3750 VRMS
Type Wet ContactOpen Collector
Operating Temperature 25 ~ +75 °C
Watchdog Timer Module, Communication (Programmable)
Status Run, Ethernet
Ports 1 x RJ-45, 10/100 Base-TX
Consumption 0.9 W
Dimensions (mm) 52 x 95 x 27 (W x L x H)
Storage Temperature 30 ~ +80 °C
Humidity 10 to 90% RH, Non-condensing
Reverse Polarity Protection Yes
ESD (IEC 61000-4-2) ±4 kV Contact for each Terminal±8 kV Air for Random Point
Channels 2
Input Impedance 10 kΩ
Overvoltage Protection +60 VDC+70 VDC
Powered from Terminal Block +12 to +48 VDC
Sink/Source (NPN/PNP) Sink/SourceSink
ON Voltage Level +10 to +50 VDC
OFF Voltage Level +4 VDC (max.)
Load Voltage +5 to +30 VDC
Load Current 100 mA/Channel
Protocol Modbus TCP, Modbus UDP, and MQTT
Frequency 3.5 kHz (without filter)
EFT (IEC 61000-4-4) ±4 kV for Power Line
Max. Counts 4,294,967,295 (32-bit)
Min. Pulse Width 0.15 ms
Access Control Password and IP Filter
Built-in Web Server Yes

Ethernet I/O Module

This Ethernet I/O module provides digital input and output over the network, making it well suited for monitoring and control in industrial applications. The module communicates via Modbus TCP, Modbus UDP and MQTT, allowing easy integration into existing SCADA and automation systems.


2 x Digital Input · 2 x Open Collector Output · Modbus TCP/UDP and MQTT · DIN-Rail Mounting


Features that make the difference

  • Wet contact inputs -detect voltage from +10 to +50 VDC with high noise immunity
  • Open collector outputs -drive relays and actuators up to 30 VDC
  • Built-in web server -easy configuration directly via browser
  • High isolation of 3750 Vrms -protects against noise and voltage spikes
  • Programmable watchdog timer -ensures stable operation during communication faults


Application areas

The module suits tasks where digital signals need to be monitored and controlled remotely over Ethernet.

  • Industrial automation and process monitoring
  • Building automation and alarm systems
  • Remote control of pumps and valves
  • Integration into SCADA and MES systems


Robust construction and flexible communication make this module a reliable choice for industrial I/O control.