Item number ETHER-MODUL-ANALO-INPUT

Ethernet I/O Module 4 x Analog Input, 5 x DI, 5 x DO Modbus TCP

4 x Analog Input, 12-bit, Voltage/Current
5 x Digital Input, Dry/Wet Contact
5 x Digital Output, Isolated Open Collector
Modbus TCP/UDP Protocol
Built-in Web Server
Programmable Watchdog Timer
2-way Isolation: Ethernet 1500VDC, I/O 2500VDC
1 x RJ-45 10/100 Base-TX
10-30VDC via Terminal Block
72 x 123 x 35 mm
-25 to 75C (special components required)

364.48 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Installation DIN-Rail Mounting
Type Isolated Open CollectorVoltageCurrentDry ContactWet Contact
Operating Temperature 25 ~ +75 °C
Resolution 12-bit
Range +0 ~ +5 VDC, ±5 VDC, +0 ~ +10 VDC, ±10 VDC0 ~ 20 mA, 4 ~ 20 mA(Jumper Selectable)
Watchdog Timer Module, Communication (Programmable)
Status Run, Ethernet
Ports 1 x RJ-45, 10/100 Base-TX
Consumption 4.3 W (max.)
Dimensions (mm) 72 x 123 x 35 (W x L x H)
Storage Temperature 30 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
Overload Protection 1.4 A
Short-circuit Protection Yes
Reverse Polarity Protection Yes
ESD (IEC 61000-4-2) ±4 kV Contact for each terminal ±8 kV Air for random point
Channels 45
Accuracy ±0.1% of FSR
Overvoltage Protection +60 VDC+30 VDC
Voltage Output Capability 10 V @ 20 mA
Current Load Resistance 500 Ω
Power-on Value Programmable
Safe Value Programmable
Powered from Terminal Block +10 ~ +30 VDC
Sink/Source (NPN/PNP) Sink
ON Voltage Level Dry: Close to GNDWet: +1 VDC (max.)
OFF Voltage Level Dry: OpenWet: +3.5 ~ +30 VDC
Effective Distance 500m (max.)
Load Voltage +5 ~ +50 VDC
Load Current 600 mA/channel
Power on Value Programmable
Individual Channel Configuration Yes
Protocol Modbus TCP, Modbus UDP
Open Wire Detection For 4 ~ 20 mA only
Frequency 100 Hz
2-way Isolation Ethernet: 1500 VDCI/O: 2500 VDC
EFT (IEC 61000-4-4) ±4 kV for Power Line
Surge (IEC 61000-4-5) ±0.5 kV for Power Line
Max. Counts 4,294,967,295 (32-bit)
Min. Pulse Width 5 ms
Access Control ID, Password and IP Filter
Built-in Web Server Yes

Ethernet I/O Module

This Ethernet I/O module combines analog and digital channels in a rugged DIN-rail unit for industrial monitoring and control. It communicates via Modbus TCP/UDP and is well suited for remote automation tasks.


4 x Analog Input · 5 x Digital Input · 5 x Digital Output · Modbus TCP/UDP


Features that ensure reliable operation

  • Isolated design -protects against voltage spikes with 1500VDC and 2500VDC isolation
  • Built-in web server -makes configuration and monitoring easy without extra software
  • Programmable watchdog -ensures automatic recovery from communication failures
  • Flexible analog inputs -jumper selectable between voltage and current
  • Protected digital outputs -short-circuit and overvoltage protected for long service life


Application areas in industry

The module fits applications where analog and digital signals need to be reliably monitored and controlled over Ethernet.

  • Process monitoring in production plants
  • Remote control of pumps and valves
  • Building automation
  • Data acquisition in distributed systems


A rugged and flexible solution for industrial I/O over Ethernet.