Item number ANALO-INPUT-MODUL-CH-2

Analog Input Module 8-CH Differential/16-CH Single-ended, Ethernet, 16-bit, -25 to 75°C

8 differential or 16 single-ended CH
Voltage/current type, DIP selectable
Range: +/-150mV to +/-10V, 4-20mA
16-bit resolution, 0.1% FSR accuracy
Sampling: 20Hz normal, 200Hz fast
2 x RJ45 10/100 switch ports, LAN bypass
Modbus TCP/UDP, MQTT, SNMP V2c
Isolation: Ethernet 1500VDC, I/O 3000VDC
Metal casing, DIN-rail/wall mount
10-90% RH non-condensing
-25 to +75C (special components required)
10-48VDC, 3.3W max, 33x127x117mm

393.96 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU 32-bit ARM
Installation DIN-Rail mounting / Wall mounting (Optional ASO-0015)
Type Voltage, Current(DIP switch selectable)
Operating Temperature 25 ~ +75 °C
Resolution 16-bit
Range Voltage: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 VCurrent: ±20 mA, 0 ~ +20 mA, +4 ~ +20 mA
Watchdog Timer Module, Communication (Programmable)
Status Run, Ethernet
Ports 2 x RJ-45, 10/100 Base-TX, Switch Ports
Consumption 3.3 W (max.)
Dimensions (mm) 33 x 127 x 117 (W x L x H)
Storage Temperature 40 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
Reverse Polarity Protection Yes
ESD (IEC 61000-4-2) ±4 kV Contact for each Terminal±8 kV Air for Random Point
Channels 8 Differential or 16 Single-ended(Software selectable, *Note 1)
Accuracy ±0.1% of FSR
Sampling Rate Normal Mode: 20 Hz (total channels)Fast Mode: 200 Hz (total channels)
Input Impedance Voltage: 2 MΩ (Differential), 1 MΩ (Single-ended)Current: 137 Ω (Differential)
Overvoltage Protection 120 VDC
Powered from Terminal Block +10 ~ +48 VDC
Overcurrent Protection 50 mA at 110 VDC (max.)
Individual Channel Configuration Yes
Protocol Modbus TCP, Modbus UDP, MQTT, SNMP V2c
Casing Metal
Common Voltage Protection ±200 VDC
2-way Isolation Ethernet: 1500 VDCI/O: 3000 VDC
EFT (IEC 61000-4-4) ±4 kV for Power Line
Surge (IEC 61000-4-5) ±2 kV for Power Line
LAN bypass Yes
Access Control Password and IP Filter
Built-in Web Server Yes

Analog input module

This analog input module is designed to measure voltage and current in industrial networks over Ethernet. It is used for monitoring and data acquisition in automation and process plants where accurate measurements are essential.


8 differential / 16 single-ended channels · 16-bit resolution · Modbus TCP/UDP, MQTT, SNMP · -25 to +75°C


Features that make the difference

  • Flexible channels - software and DIP switch selectable voltage or current configuration per channel
  • High accuracy - 16-bit resolution with ±0.1% of full scale range accuracy
  • Robust isolation - 1500 VDC Ethernet and 3000 VDC I/O isolation protects against noise and transients
  • Built-in web server - easy configuration and monitoring directly via browser
  • LAN bypass - keeps the network connection alive even if the module loses power


Application areas

The module fits industrial environments that require stable data acquisition and reliable operation under demanding conditions.

  • Process and production monitoring
  • Automation systems with Modbus/MQTT integration
  • Remote measurement stations
  • Installations with extreme temperature conditions


A reliable choice for precise and robust analog signal measurement in industrial Ethernet networks.