Item number RS-232-RS-485-3

RS-232/RS-485 to CAN Converter with Isolation, -40 to 75°C

RS-232/RS-485 to CAN converter
NXP SJA1000T controller, 16 MHz
CAN 2.0A/2.0B, ISO-11898-2
Baud rate up to 1 Mbps
1000VDC/2500Vrms isolation
120 Ohm terminal resistor jumper
1 x RJ-45 10/100Base-T(X) port
Metal casing, wall mount
10-30VDC power input
-40 to 75C operating temp
102 x 125 x 28 mm

439.52 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Controller NXP SJA1000T with 16 MHz clock
Installation Wall Mount
Isolation 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Operating Temperature -40 ~ +75 °C
Terminal Resistor Jumper for 120 Ω terminal resistor
Status 1 x Power
Ports 1 x RJ-45, 10/100Base-T(X)11 x RS-2321 x RS-485 (self-turner ASIC inside)
Input Range +10 VDC ~ +30 VDC
Consumption 2.5 W
Dimensions (mm) 102 x 125 x 28 (W x L x H)
Storage Temperature -40 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
Specification ISO-11898-2, CAN 2.0A and CAN 2.0B
Baud Rate 10 k ~ 1 M bps110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Parity None, Even, Odd
Data Bit 7, 8
Stop Bit 1
Casing Metal
Filter Yes

RS-232 to CAN Converter

This RS-232 to CAN converter is designed to bridge serial RS-232 and RS-485 devices with CAN bus networks in industrial automation systems. It provides reliable data conversion with galvanic isolation, protecting connected equipment from voltage spikes and ground loops. The module is built for continuous operation in demanding environments such as factories, transportation systems and process control installations.


RS-232/RS-485 to CAN · NXP SJA1000T controller · 1000VDC isolation · -40 to 75°C operation


Key features and benefits

  • Dual isolation - 1000VDC DC-to-DC and 2500Vrms photocoupler isolation protect against surges
  • Wide baud rate support - configurable from 10 kbps to 1 Mbps for flexible network design
  • Built-in terminal resistor - jumper-selectable 120 Ohm resistor simplifies bus termination
  • Robust controller - NXP SJA1000T with 16 MHz clock ensures stable CAN communication
  • Rugged metal housing - wall-mountable enclosure withstands harsh industrial conditions


Typical applications

The converter fits well into industrial networks that require reliable communication between serial equipment and CAN bus systems.

  • Factory automation and machine control
  • Building management systems
  • Transportation and vehicle networks
  • Process monitoring and SCADA integration


A dependable choice for engineers who need stable, isolated conversion between RS-232/RS-485 and CAN networks.