Item number CAN-BUS-GATEW-DEVIC

CAN Bus Gateway, DeviceNet to Modbus TCP/RTU/ASCII, DIN-Rail

DeviceNet to Modbus TCP/RTU/ASCII
NXP SJA1000T CAN controller, 16MHz
1 x RJ-45 10/100Base-T(X) Ethernet
1 x RS-232, 1 x RS-485
Modbus TCP, ASCII, RTU protocols
Isolation 1000VDC DC-DC, 2500Vrms
120 Ohm terminal resistor jumper
Watchdog timer
DIN-Rail installation
10-30VDC power input
-25~+75C (special components required)
72 x 122 x 33 mm

434.16 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU 80186, 80 MHz or compatible
Controller NXP SJA1000T with 16 MHz clock
Installation DIN-Rail
Isolation 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Operating Temperature -25 ~ +75 ℃
Terminal Resistor Jumper for 120 Ω terminal resistor
Watchdog Timer Yes
Status 1 x Power2 x DeviceNet status
Ports 11 x RJ-45, 10/100Base-T(X) (Auto-negotiating, Auto_MDIX)1 x RS-2321 x RS-485
Input Range +10 VDC ~ +30 VDC
Consumption 2.5 W
Dimensions (mm) 72 x 122 x 33 (W x L x H)
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing
Specification Volume I, Release 2.0 & Volume II, Release 2.0
Parity None, Even, Odd
Data Bit 7, 8
Stop Bit 1, 2
Protocol Modbus TCPModbus ASCII / Modbus RTU
EEPROM 16 KB
Connection Supported 1 connection for Explicit Messaging1 connection for Polled I/O
Shutdown Message Yes
Subscribe Group 2 Only Server
Heartbeat Message Yes

CAN Bus Gateway

This CAN Bus Gateway connects DeviceNet networks to Modbus TCP, RTU and ASCII systems, allowing seamless data exchange between industrial control devices. It is designed for reliable operation in demanding automation environments.


DeviceNet to Modbus TCP/RTU/ASCII · NXP SJA1000T CAN Controller · DIN-Rail Mount · -25 to +75C Operation


Key Features

  • Protocol Conversion - bridges DeviceNet and Modbus TCP/RTU/ASCII networks
  • Isolated Design - 1000VDC DC-to-DC and 2500Vrms photo-coupler isolation protects connected equipment
  • Dual Serial Ports - built-in RS-232 and RS-485 interfaces for flexible wiring
  • Watchdog Timer - ensures automatic recovery from system faults
  • Terminal Resistor Jumper - simplifies CAN bus termination with a 120 Ohm jumper


Typical Applications

The gateway is suitable wherever DeviceNet devices need to communicate with Modbus-based control systems.

  • Factory automation networks
  • Building management systems
  • Machine-to-machine data integration
  • Industrial process monitoring


A robust choice for integrating DeviceNet and Modbus networks in industrial environments.