Item number DEVIC-MODBU-TCP-RTU

DeviceNet to Modbus TCP/RTU/ASCII Gateway with DIN-Rail Mount

DeviceNet to Modbus TCP/RTU gateway
CPU: 80186, 80MHz compatible
NXP SJA1000T CAN controller, 16MHz
1 x RJ-45 10/100Base-T(X) port
1 x RS-232, 1 x RS-485 ports
Isolation: 1000VDC / 2500Vrms
120 Ohm terminal resistor jumper
DIN-Rail mounting
Operating temp: -25 to +75C
Input: +10 to +30VDC, 2.5W
Dimensions: 72 x 122 x 33 mm
Humidity: 10-90% RH non-condensing

440.86 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU 80186, 80 MHz or compatible
Controller NXP SJA1000T with 16 MHz clock
Installation DIN-Rail
Isolation 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Operating Temperature -25 ~ +75 ℃
Terminal Resistor Jumper for 120 Ω terminal resistor
Watchdog Timer Yes
Status 1 x Device status2 x DeviceNet status
Ports 11 x RJ-45, 10/100Base-T(X) (Auto-negotiating, Auto_MDIX)1 x RS-2321 x RS-485
Input Range +10 VDC ~ +30 VDC
Consumption 2.5 W
Dimensions (mm) 72 x 122 x 33 (W x L x H)
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing
Specification Volume I, Release 2.0 & Volume II, Release 2.0
Parity None, Even, Odd
Data Bit 7, 8
Stop Bit 1, 2
Protocol Modbus TCPModbus ASCII / Modbus RTU
EEPROM 16 KB
Connection Supported 1 connection for Explicit Messaging1 connection for Polled I/O1 connection for Bit-Strobe I/O1 connection for COS/Cyclic I/O

CAN Bus Gateway

This CAN Bus Gateway connects DeviceNet networks to Modbus TCP, RTU and ASCII systems, enabling seamless data exchange between industrial control devices. It is designed for demanding automation environments where reliable communication and robust isolation are essential.


DeviceNet to Modbus TCP/RTU · NXP SJA1000T CAN Controller · DIN-Rail Mounting · -25 to +75C Operating Range


Key Features

  • Protocol Conversion - translates DeviceNet traffic into Modbus TCP, RTU or ASCII
  • Dual Serial Interfaces - RS-232 and RS-485 ports for flexible wiring
  • High Isolation - 1000VDC and 2500Vrms protection against electrical noise
  • Built-in Terminal Resistor - jumper-selectable 120 Ohm resistor for stable bus termination
  • Wide Operating Range - runs reliably from -25C to +75C in harsh environments


Typical Applications

The gateway is suitable for industrial plants that need to bridge DeviceNet and Modbus based systems.

  • Factory automation networks
  • Process control systems
  • Machine building and integration
  • Building and infrastructure monitoring


A dependable choice for integrating DeviceNet and Modbus networks in industrial environments.