Item number CANOP-ANALO-OUTPU-MODUL

CANopen Analog Output Module, 4-Channel, 14-bit Isolated

CANopen protocol CiA 301 / CiA 401
4 x isolated analog output channels
Output: 0-10V, +/-10V, 0-5V, +/-5V
Current output: 0-20mA, 4-20mA
14-bit resolution
Accuracy +/-0.1% V, +/-0.2% mA
3000VDC isolation
Built-in 120 Ohm terminal resistor
Node ID 1-99, Baud 10k-1M
Hardware watchdog, 3 status LEDs
33 x 99 x 78 mm
-25/+75C (special components required)

426.12 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Installation DIN-Rail
Isolation 3000 VDC3000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Type 0~ 5 V, +/- 5 V, 0~ 10 V, +/- 10 V, 0 ~ 20 mA, 4 ~ 20 mA
Operating Temperature -25 ~ +75 °C
Resolution 14-bit
Terminal Resistor Built-in 120Ω
Watchdog Timer Hardware watchdog
Status 3 LEDs to PWR, RUN and ERR
Consumption 2.5 W
Dimensions (mm) 33 x 99 x 78 ( W x L x H )
Storage Temperature -30 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
Channels 4
Accuracy +/- 0.1 % of FSR for voltage output ; +/- 0.2 % of FSR for current output
Zero Drift Voltage: +/-30μV/°CCurrent:: +/-0.2μV/°C
Span Drift +/-20ppm/°C
Voltage Output Capability 10V@ 5mA
Current Load Resistance External +24 V : 1050 Ohms
Power-on Value Yes
Baud Rate 10 k ~ 1 M
Protocol CiA 301 v4.02, CiA 401 v2.1
Node ID 1 ~ 99
No. of PDOs 10 RxPDO , 10 TxPDO
Error Control Node Guarding protocol or Heartbeat Producer
NMT Slave
EMCY Message Yes
PDO Mode Event Triggered, Remotely requested, Cyclic and acyclic SYNC

CANopen Analog Output Module

This CANopen Analog Output Module converts digital control signals into precise analog voltage or current outputs for industrial automation systems. It is designed for reliable integration into CAN bus networks where accurate signal conversion is required.


4 Channels · 14-bit Resolution · CANopen CiA 301/401 · 3000VDC Isolation


Key Features

  • Hardware Watchdog - ensures automatic recovery from faults
  • 3 Status LEDs - quick visual diagnostics for power, run and error
  • Node Guarding / Heartbeat - reliable error monitoring on the bus
  • Configurable Output Types - supports voltage and current signals
  • DIN-Rail Mounting - simple and space-saving installation


Typical Applications

The module fits seamlessly into CAN bus based control systems where analog output signals are needed.

  • Industrial automation
  • Process control systems
  • Machine building
  • Building automation