Item number PORT-CAN-BUS-CONTR-2

1-Port CAN Bus Controller, Isolated, NXP SJA1000T, -25~75°C

CPU: 80186, 80MHz or compatible
Controller: NXP SJA1000T, 16MHz clock
1 x CAN port, ISO-11898-2
CAN 2.0A and CAN 2.0B support
Baud rate 10kbps to 1Mbps
Isolation 3000VDC / 2500Vrms
120 Ohm terminal resistor jumper
EEPROM 2KB, Flash 512KB, SRAM 512KB
Real time clock
Consumption: 2W
Dimensions: 31 x 91 x 115 mm
-25~75°C (special components required)

304.18 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU 80186, 80 MHz or compatible
Controller NXP SJA1000T with 16 MHz clock
Flash 512 KB
Isolation 3000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Driver For I-8000/ iP-8000/ ViewPAC-2000/ WinPAC-8000/ LinPAC-8000/ XPAC-8000-CE6
Operating Temperature -25 ~ +75 °C
Terminal Resistor Jumper for 120 Ω terminal resistor
SDK TC/BC, GCC, VB.Net 2003, C#.Net 2003, VB.Net 2005, C#.Net 2005, eVC++ 4.0
Real Time Clock Yes
Status 1 x Power1 x CAN status1 x Operating mode
Ports 1
Consumption 2 W
Dimensions (mm) 31 x 91 x 115 (W x L x H)
Storage Temperature -30 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
Specification ISO-11898-2, CAN 2.0A and CAN 2.0B
Baud Rate 10 k ~ 1 M bps
EEPROM 2 KB
SRAM 512 KB

Embedded CAN Bus Controller

This embedded CAN bus controller provides a single isolated CAN port for industrial automation and monitoring systems. It is designed for reliable data communication in demanding environments and supports standard CAN protocols. The module can be integrated into a wide range of industrial control platforms.


1 x CAN Port · NXP SJA1000T Controller · 3000VDC Isolation · -25 to 75°C Operation


Key Features

  • NXP SJA1000T Controller - reliable CAN communication at 16MHz clock speed
  • Galvanic Isolation - 3000VDC DC-to-DC and 2500Vrms photo-couple isolation protects against transients
  • Wide Baud Rate Range - supports 10kbps to 1Mbps for flexible network configuration
  • Built-in Terminal Resistor - jumper-selectable 120 Ohm resistor simplifies bus termination
  • Wide Operating Temperature - operates from -25°C to +75°C for harsh environments


Typical Applications

The controller is suitable for industrial CAN bus networks where robust and isolated communication is required.

  • Factory automation systems
  • Vehicle and mobile machinery control
  • Building automation and monitoring
  • Industrial process control networks


A robust and isolated solution for reliable CAN bus communication in industrial environments.