Item number CO2-TEMPE-HUMID-SENSO-2

CO2/Temperature/Humidity Sensor with Data Logger, PoE Ethernet, RS-485

CO2, temperature and humidity sensor
CO2 range 0-9999 ppm NDIR
Temperature range 10 to 50C
Humidity range 0-100% RH
Data logger up to 450,000 records
Real time clock built-in
1 x Relay output SPST 16A
RS-485 Modbus RTU, DCON
Ethernet Modbus TCP and MQTT, PoE
12-48VDC or PoE powered
Dim. Ø150 x 53 mm
IP20, ceiling/wall mounting

479.72 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Alarm CO2/RH/Temperature
Installation Ceiling Mounting/Wall Mounting
Operating Temperature 0 ~ 50°C
Resolution 1 ppm0.1°C0.1% RH, Non-condensing
Range 10 ~ +50°C0 ~ 100% RH, Non-condensing0 to 9999 ppm (NDIR)
Real Time Clock Yes
Ports 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators)1 x RS-4851 x Ethernet
Consumption Non-PoE: 1.5 W (Max.)PoE: 1.6 W (Max.)
Dimensions (mm) Ø 150 x 53 (Ø x H)
Storage Temperature 30 ~ +75°C
Humidity 10 ~ 90% RH, Non-condensing
Channels 1 x Form A, SPST30 VDC @ 16 A or 250 VAC @ 16 A
Accuracy ±5% RH, Non-condensing±0.6°C±40 ppm ±3% of measured value
Response Time 120 seconds
Powered from Terminal Block +12 ~ +48 VDC
Protocol DCON and Modbus/RTU (RS-485)Modbus TCP and MQTT (Ethernet)
Ingress Protection Rating IP20
Data Logger Yes, up to 450,000 records
Warm-up Time 5 minutes

CO2, Temperature and Humidity Sensor

This environmental sensor simultaneously measures CO2 levels, temperature and relative humidity in indoor environments. The unit is ideal for monitoring indoor air quality in offices, schools and industrial buildings, combining accurate measurements with built-in data logging and network connectivity.


CO2: 0-9999 ppm · Temperature: 10 to 50°C · Humidity: 0-100% RH · Data logger: 450,000 records


Features for reliable monitoring

  • NDIR CO2 sensor -high accuracy with ±40 ppm ±3% of measured value
  • Built-in data logger -stores up to 450,000 records for later analysis
  • Real time clock -timestamps every measurement
  • Dual communication -RS-485 Modbus RTU/DCON and Ethernet Modbus TCP/MQTT
  • PoE support -powered via network cable or 12-48VDC terminal block


Application areas

The sensor is well suited for indoor air quality monitoring where accurate measurement is essential.

  • Offices and meeting rooms
  • Schools and institutions
  • Industrial and warehouse buildings
  • Building management systems (BMS)


A reliable solution for anyone needing accurate and continuous monitoring of CO2, temperature and humidity.