This category covers remote I/O modules for measuring temperature and humidity. The modules are usually mounted on a DIN rail in a cabinet or close to the process and send their readings to a controller over Ethernet. They are used in production, ventilation and building automation where humidity or temperature needs continuous monitoring.

Choose a module based on which sensor types it supports. Some modules measure temperature only. Others measure both temperature and relative humidity. Check the number of channels, the supply voltage and the temperature range. Also check whether the module needs galvanic isolation from the rest of the system. The protocol determines how the module connects to the controller.

Temperature and Humidity
There are 29 products.
Isolated Digital I/O Board, 16-Channel USB 2.0, Modbus RTU

16 isolated digital I/O channels
Intra-module isolation 3000 VDC
USB 2.0 Full-Speed 12Mbps
Modbus RTU protocol
1x hardware watchdog, 1.6s
1x software watchdog, programmable
PWR and Error status LEDs
Windows 7/10/11, Linux driver
Power consumption 0.18W max
113 x 169 x 54 mm
Operating temp 25 to 75C
Humidity 10-95% RH non-condensing

762.46 €
Item numberISOLA-DIGIT-BOARD-16-2
On the way in
Isolated Digital I/O Board 8-Channel Thermocouple Input, USB 2.0

8 thermocouple channels
Types J, K, T, E, R, S, B, N, C, L, M
Resolution 0.1C, Accuracy 0.5C
Sampling rate 100Hz per channel
USB 2.0 Full-Speed 12Mbps
Modbus RTU protocol
Isolation 3000VDC
Hardware and software watchdog
Windows 7/10/11, Linux Kernel 2.4+
113 x 169 x 29 mm
-25 to +75C (special components required)
Power consumption 0.17W max

556.10 €
Item numberISOLA-DIGIT-BOARD-CHANN-2
On the way in
8-Channel Isolated Analog Input Module, RS-485 Modbus RTU/DCON, Thermocouple/Voltage/Current

8 x differential analog input
Voltage, current, thermocouple
Thermocouple types J,K,T,E,R,S,B,N,C,L,M
16-bit resolution
Accuracy +/-0.1% of FSR
Sampling rate 8 Hz total
1 x RS-485, Modbus RTU/DCON
3000 VDC intra-module isolation
Open wire detection (thermocouple)
10-30VDC
72 x 123 x 35 mm
-25 to 75C (special components required)

371.18 €
Item numberCHANN-ISOLA-ANALO-INPUT-2
On the way in
Analog Input Module with 5-Digit LED Display, RS-485, Thermocouple/Voltage/Current

1 x differential analog input
Voltage, current, thermocouple input
Thermocouple types J,K,T,E,R,S,B,N,C
16-bit resolution, 0.1% FSR accuracy
5-digit 7-segment LED display
1 x dry contact digital input
2 x open collector output
1 x RS-485, DCON protocol
3000 VDC intra-module isolation
10-30VDC power input
72 x 123 x 35 mm
-25 to 75C (special components required)

284.08 €
Item numberANALO-INPUT-MODUL-DIGIT
On the way in
Analog Input Module 1-Ch Voltage/Current/Thermocouple RS-485

1 x differential analog input
Voltage, current, thermocouple input
Thermocouple types J,K,T,E,R,S,B,N,C
16-bit resolution, 0.1% accuracy
10 Hz sampling rate
1 x digital input, 2 x digital output
RS-485, DCON protocol
3000 VDC intra-module isolation
10-30VDC power input
72 x 123 x 35 mm
-25 to +75C (special components required)

249.24 €
Item numberANALO-INPUT-MODUL-CH-7
On the way in
8-Channel Analog Input Module, Voltage/Current/Thermocouple, RS-485

8 differential or 6 DI + 2 SE channels
Voltage, current, thermocouple input
Thermocouple types J,K,T,E,R,S,B,N,C
16-bit resolution, 0.1% FSR accuracy
10 Hz total sampling rate
RS-485 port, DCON protocol
Baud rate 1200-115200 bps
3000 VDC intra-module isolation
ESD 4kV, EFT 4kV, surge 0.5kV
10-30VDC power input
72 x 123 x 35 mm
-25 to +75C (special components required)

273.36 €
Item numberCHANN-ANALO-INPUT-MODUL-9
On the way in
RTD Input Module with LED Display, RS-485, Modbus RTU/DCON

1 x RTD input, Pt100/Pt1000/Ni120
16-bit resolution, 0.05% FSR accuracy
5-digit 7-segment LED display
1 x Dry contact input, 16-bit counter
2 x Open collector MOSFET output
700 mA/channel, sink type
1 x RS-485, Modbus RTU/DCON
Baud rate 1200-115200 bps
3000 VDC intra-module isolation
10-30VDC power input
72 x 123 x 35 mm (W x L x H)
-25 to 75C (special components required)

302.84 €
Item numberRTD-INPUT-MODUL-LED
On the way in
RS-485 Thermocouple/Voltage Input Module, 16-bit, Modbus RTU, DIN-Rail

1 x Differential Analog Input
Voltage, Current, Thermocouple Input
Thermocouple Types J,K,T,E,R,S,B,N,C
16-bit Resolution, 0.1% FSR Accuracy
1 x Dry Contact Digital Input
2 x Open Collector Output
1 x RS-485, Modbus RTU/DCON
3000 VDC Intra-module Isolation
10 - 30VDC Power Input
72 x 123 x 35 mm
-25 - +75C (special components required)

257.28 €
Item numberRS-485-THERM-VOLTA
On the way in
Thermocouple Input Module with 5-Digit LED Display, RS-485

1 x Isolated Thermocouple/Voltage Input
Sensor Types: J, K, T, E, R, S, B, N, C
16-bit Resolution, 0.1% FSR Accuracy
1 x Dry Contact Digital Input
2 x Open Collector Digital Output
RS-485, Modbus RTU/DCON, 115200 bps
5-Digit 7-Segment LED Display
3000VDC Intra-module Isolation
10-30VDC Power Input
72 x 123 x 35 mm
25-75C Operating Temperature
DIN-Rail Mounting

292.12 €
Item numberTHERM-INPUT-MODUL-DIGIT
On the way in
8-Channel Thermistor Input Module with 6 x Open Collector Output, RS-485

8 x Thermistor Input Channels
16-bit Resolution, +-0.1% FSR
Sampling Rate 8 Hz Total
6 x Open Collector Output
Load 3.5-50VDC, 650mA/Channel
1 x RS-485, Modbus RTU/DCON
Baud Rate 1200-115200 bps
Intra-module Isolation 3000VDC
Open Wire Detection
10-30VDC Power Input
72 x 123 x 35 mm
-25 to 75C (special components required)

326.96 €
Item numberCHANN-THERM-INPUT-MODUL
On the way in
3-Channel RTD Input Module with RS-485, LED Display, DIN-Rail

3 x RTD channels (Pt100, Pt1000, Ni120)
16-bit resolution, 0.1% FSR accuracy
Sampling rate 15 Hz
1 x RS-485, Modbus RTU/DCON
Baud rate 1200-115200 bps
5-digit 7-segment LED display
Open wire detection
3-wire RTD lead resistance elimination
3000 VDC intra-module isolation
10-95% RH, non-condensing
-25 to +75C (special components required)
10-30VDC, 1.6W

353.76 €
Item numberCHANN-RTD-INPUT-MODUL-7
On the way in
16-Channel Thermocouple/Voltage/Current Input Module RS-485

16 x Differential analog input channels
Thermocouple J,K,T,E,R,S,B,N,C
Voltage +-15mV to +-2.5V
Current +-20mA, 0-20mA, 4-20mA
16-bit resolution, 0.1% FSR accuracy
Sampling rate 10 Hz
1 x RS-485, Modbus RTU/DCON
Baud rate 1200-115200 bps
Open wire detection
Reverse polarity protection
10-48VDC power input
116 x 120 x 64 mm

340.36 €
Item number16-CHANN-THERM-VOLTA-2
On the way in
RTD Repeater Module RS-485, 1-Channel Pt100/Pt1000/Ni120, 16-bit

1-channel RTD input via RS-485
Pt100, Pt1000, Ni120 sensors
16-bit resolution, 10 Hz sampling
Accuracy +/-0.05% of FSR
1 x Digital input, dry contact
2 x Open collector output, 700mA
Modbus RTU, DCON protocol
Open wire detection
3000VDC intra-module isolation
10-30VDC input, 0.6W
72 x 123 x 35 mm
-25 to +75C (special components required)

268.00 €
Item numberRTD-REPEA-MODUL-RS
On the way in
3-Channel RTD Repeater Module, Pt100/Pt1000/Ni120, RS-485

3-channel RTD input repeater
Sensor types: Pt100, Pt1000, Ni120
16-bit resolution, 0.1% FSR accuracy
Resistance measurement up to 3.2 kOhm
Sampling rate 15 Hz
1 x RS-485, Modbus RTU / DCON
Open wire detection
3-wire RTD lead resistance elimination
Intra-module isolation 3000 VDC
Input 10-30VDC, 1.0W
72 x 123 x 35 mm
-25 to 75C (special components required)

318.92 €
Item numberCHANN-RTD-REPEA-MODUL
On the way in
4-Channel DS18B20 Temperature Sensor Repeater, RS-485 Modbus RTU/DCON

4 channel DS18B20 sensor repeater
Up to 20 sensors per port
Max. 100m sensor wiring per port
12-bit resolution, +-0.5C accuracy
1 x RS-485, Modbus RTU, DCON
Baud rate 1200-115200 bps
Sampling rate 1 Hz
3000VDC intra-module isolation
Reverse polarity protection
10-90% RH non-condensing
72 x 123 x 35 mm
+10 ~ +48VDC, 0.5W

188.94 €
Item numberCHANN-DS18B-TEMPE-SENSO
On the way in
16-CH Differential Thermocouple/Voltage/Current Input Module RS-485

16 x Differential Analog Input
Voltage, Current, Thermocouple
Thermocouple types: J,K,T,E,R,S,B,N,C
16-bit resolution, +/-0.1% FSR
Sampling rate: 10 Hz total
1 x RS-485, Modbus RTU/DCON
Baud rate: 1200-115200 bps
Open wire detection (thermocouple)
3000VDC intra-module isolation
10-30VDC, 0.5W
76 x 120 x 42 mm
25-75C (special components required)

322.94 €
Item number16-CH-DIFFE-THERM
On the way in
16-Channel Thermocouple/Voltage Input Module RS-485, Modbus RTU, DCON

16 x Differential Analog Input
Thermocouple J,K,T,E,R,S,B,N,C
Voltage +-15mV to +-2.5V
Current 0-20mA, 4-20mA
16-bit Resolution, 0.1% FSR
1 x RS-485, Modbus RTU/DCON
Baud Rate 1200-115200 bps
3000VDC Intra-module Isolation
DIN-Rail Mounting
10-48VDC Input, 0.5W
31 x 157 x 132 mm
-25 to 75C (special components required)

340.36 €
Item number16-CHANN-THERM-VOLTA
On the way in
DS18B20 Temperature Repeater Module 4-Port RS-485 Modbus RTU

4 x DS18B20 sensor ports
Up to 20 sensors per port
Max. 100m cable per port
12-bit resolution
Accuracy +/-0.5C
1 x RS-485, Modbus RTU/DCON
Baud rate 1200-115200 bps
Isolation 3000VDC
DIN-Rail mounting
10-48VDC
-25 to 75C (special components required)
33 x 117 x 88 mm

226.46 €
Item numberDS18B-TEMPE-REPEA-MODUL
On the way in
8-Channel Thermocouple/Voltage/Current Input Module RS-485, 16-bit

8 Differential or 6 Diff + 2 Single-ended
Thermocouple types J,K,T,E,R,S,B,N,C,L,M
Voltage +/-15mV to +/-2.5V
Current +/-20mA (ext. resistor req.)
16-bit resolution
Accuracy +/-0.1% of FSR
Sampling rate 10 Hz
1 x RS-485, DCON protocol
3000 VDC intra-module isolation
10-30VDC power input
72 x 123 x 35 mm
-25 to +75C (special components required)

280.06 €
Item numberCHANN-THERM-VOLTA-CURRE-2
On the way in
8-Channel Thermistor Input Module RS-485, Modbus RTU/ASCII, DCON

8 x Thermistor input channels
16-bit resolution, +/-1% accuracy
Sampling rate 8 Hz total
1 x RS-485 port
Modbus RTU, Modbus ASCII, DCON
Baud rate 1200 - 115200 bps
Individual channel configuration
Open wire detection
2500 VDC intra-module isolation
DIN-rail mounting
10-30VDC
52 x 98 x 27 mm

170.18 €
Item numberCHANN-THERM-INPUT-MODUL-2
On the way in
Showing 1-20 of 29 item(s)