Item number 16-CH-DIGIT-INPUT-4

16-ch Isolated (Wet, 10~80 VAC/±15~±80VDC) DI and 2-ch (Sink, NPN) DO Module with LED Display, RS-485, DCON/Modbus RTU

16 x Digital Input, Wet Contact
2 x Isolated Open Collector Output
Sink/Source Input Type
1 x RS-485, Modbus RTU/DCON
Baud Rate 1200-115200 bps
3750VDC Intra-module Isolation
Programmable Watchdog Timer
Overvoltage and Short-circuit Protection
10-30VDC Power Input
76 x 121 x 42 mm
-25 to 75C (special components required)
DIN-Rail Mounting

184.92 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Installation DIN-Rail Mounting
Type Wet ContactIsolated Open Collector
Operating Temperature 25 ~ +75 °C
Watchdog Timer Module, Communication (Programmable)
Status 1 x Power and Communication16 x Digital Input
Ports 1 x RS-485
Input Range +10 ~ +30 VDC
Consumption 0.4 W
Dimensions (mm) 76 x 121 x 42 (W x L x H)
Storage Temperature 40 ~ +85 °C
Humidity 10 ~ 95% RH, Non-condensing
Overload Protection 1.4 A
Short-circuit Protection Yes
Reverse Polarity Protection Yes
Intra-module Isolation 3750 VDC
ESD (IEC 61000-4-2) ±4 kV Contact for each Terminal±8 kV Air for Random Point
Channels 162
Input Impedance 30 kΩ
Overvoltage Protection 120 VAC/VDC max.60 VDC
Safe Value Programmable
Sink/Source (NPN/PNP) Sink/SourceSink
ON Voltage Level 10 ~ 80 VAC±15 ~ ±80 VDC
OFF Voltage Level 3 VAC max.±3 VDC max.
Load Voltage +5 ~ +50 VDC
Load Current 600 mA/channel
Power on Value Programmable
Baud Rate 1200 ~ 115200 bps
Data Format (N, 8, 1), (N, 8, 2), (E, 8, 1), or (O, 8, 1)
Protocol Modbus RTU, DCON
Frequency 100 Hz
EFT (IEC 61000-4-4) ±4 kV for Power Line
Surge (IEC 61000-4-5) ±2 kV for Power Line
Max. Counts 65535 (16-bit)
Min. Pulse Width 5 ms

Repeater Module

This repeater module is designed to monitor digital signals in industrial environments and forward data via a robust RS-485 connection. It is used to expand the number of digital inputs in automation and monitoring tasks where reliability and signal isolation are essential.


16 x Digital Input · 2 x Isolated Output · RS-485 Modbus RTU · DIN-Rail Mounting


Features that make it a solid choice

  • 16 digital inputs - monitors wet contact signals with high reliability
  • Isolated output - 2 channels with open collector protect against overvoltage
  • RS-485 communication - supports Modbus RTU and DCON protocols
  • High isolation voltage - 3750 VDC intra-module isolation ensures stable operation
  • Programmable watchdog - monitors communication and resets automatically on failure


Applications for industrial monitoring

The module fits tasks where many digital signals must be collected reliably over long distances via serial communication.

  • Industrial automation and process monitoring
  • Remote monitoring of sensors and contacts
  • Distributed I/O systems
  • SCADA and PLC integration


With its robust protection and reliable RS-485 communication, this module is the right choice for demanding industrial installations.