Item number RS-485-RELAY-MODUL

RS-485 Relay Module 4x Power Relay Output, AC Digital Input, Modbus RTU/DCON

4 x Power Relay Output, Form C
Contact rating 20A(NO)/16A(NC) 250VAC
1 x Digital Input, Wet Contact 90-240VAC
1 x RS-485, Modbus RTU or DCON
Baud rate 1200-115200 bps
Electrical endurance 100,000 ops
Mechanical endurance 10,000,000 ops
Isolation 5000 Vrms
10-30VDC, 2.4W Max
DIN-Rail installation
-25C to +75C operating temperature
116 x 122 x 64 mm

123.28 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Installation DIN-Rail
Isolation 5000 VRMS
Type Wet Contact, 90 ~ 240 VACPower Relay, 4 Form C
Operating Temperature 25°C ~ +75°C
Range 40°C ~ +80°C, Thermistor
Status Power: 1 LED as Power IndicatorDigital Output: 4 LED as digital output indicator
Ports 1 x RS-485
Input Range +10 ~ +30 VDC
Consumption 100 mA @ 24 VDC (2.4 W Max.)
Dimensions (mm) 116 x 122 x 64 (W x L x H)
Storage Temperature 30°C ~ +80°C
Humidity 10 ~ 90% RH, Non-condensing
ESD (IEC 61000-4-2) ±4 kV Contact for Each Terminal
Channels 41
Accuracy ±0.3°C at 25°C, Max. ±2°C
Input Impedance 68 KΩ, 1 W
ON Voltage Level 85 VAC
OFF Voltage Level 60 VAC
Power on Value Yes
Baud Rate Hardware Configuration: Fixed 9600 bpsSoftware Configuration: 1200 ~ 115200 bps
Data Format (N,8,1), (O,8,1), (E,8,1), (N,8,2)
Protocol Modbus RTU or DCON
Contact Rating 20 A (NO)/16 A (NC) @ 250 VAC (Recommend Working Current 5 A)
Operate Time 20 ms Max.
Release Time 10 ms Max.
Electrical Endurance 100,000 ops
Mechanical Endurance 10,000,000 ops
Function Local and remote direct control relay ON/OFF and remote status monitoring.
EFT (IEC 61000-4-4) ±1 kV for power and communication

Repeater Module

This repeater module is designed for local and remote ON/OFF relay control as well as remote status monitoring. It is used in industrial automation systems where reliable contact and signal control is essential.


4 x Power Relay Output · RS-485 Modbus RTU/DCON · 10-30VDC · DIN-Rail


Features that make the difference

  • 4 x Form C relay outputs - handles up to 20A at 250VAC
  • Digital input with wet contact - supports 90-240VAC signals
  • High isolation - 5000 Vrms protects against electrical noise
  • Robust EFT/ESD protection - ensures stable operation in noisy environments
  • Flexible communication - RS-485 with Modbus RTU or DCON protocol


Application areas

The module suits applications where relay control and status monitoring must work reliably over long distances.

  • Industrial automation
  • Building management
  • Remote equipment monitoring
  • Distributed ON/OFF control


A robust and flexible choice for reliable relay control in industrial environments.