Battery for log-wlxxx series
in normal battery change Log-data not
19.03 €
Item numberLOG-LS14250

Battery for log-wlxxx series
in normal battery change Log-data not
Stand-Alone Temperature data logger
memory for 16,000 measurements
Use eg. Log-50U for setup and emptying
Log interval: 1 second to 60 minutes in 15 Step
Battery life: Depending on log interval
Typical battery life: 2 - 4 years
Dim: 62 x 47 x 19 mm
Weight: 45 g
Operating temperature for data logger: -40 - +80°C
IP64
Residual sale
2 channel temperature logger with external sensor
Temperature sensor: -40 - + 140 ° C
Freedding temperature: -40 - + 80 ° C
1 x RJ45 Ethernet
1 x Power Jack 3.5 / 1.5 mm 6VDC
Wireless data logger for humidity, temperature and CO2 measurement
Additional purchase Data collector for retrieving measurement data.
Data collector can be connected to T&D Cloud or PC
Operating time on battery alone is 2 days.
Additional power supply: LOG-DC5V
Wireless transfer of data to Data Collector
Wireless Pulse Logger with memory
Max. number of pulses per measurement interval: 61439 pulses
Max. Frequency: 3.5kHz (0.3ms)
Sending measurement data to Data Collector (Base Station) at 870MHz
Distance between Data Logger and Data collector up to 150 meters
Battery operation up to 10 months at an upload per day
Data Logger is not on-line
16,000 measurements in memory with the date and time stamp
Removable external terminal block. Close O-ring
Free Cloud service: TD WebStorage for Data Collector
LCD display shows current measurements
PC software: tools and presentation included
Dimensions: 62 x 47 x 19 mm
Fixed antenna: 24 mm
Battery type: LS14250 x 1
Radio base station retrieves Log data from loggers
base station is a link between loggers and PC
base station data from 100 wireless loggers
Frequency Band Base Station and Data Logger is 870MHz
Up to 150meter - depending on conditions
Greater distance with repeaters (radio-relay stations)
interface for presentation PC is Wifi
USB interface to PC for setup:
base station, connection dock for Data Like (Optical)
Protocol: SMTP (POP before SMTP-AUTH (login) FTP, SNTP, DHCP, DNS)
temperature: -10 - + 60 ° C
Dimensions: 102 x 83 x 28 mm
Power supply included
Only for T&D loggers
Wireless Temperature Logger with memory
Sending measurement data to the data collector (base station) at 870MHz
Distance between the data logger and data collector up to 150 meters
Data Logger is not on-line
8,000 measurements per type of the memory with date and time stamp
Luminance: 0 - 130.000Lux
UV intensity: 0 - 30mW / cm 2
External sensors
Free Cloud service: TD WebStorage for Data collector
LCD display shows current measurements
PC software: tools and presentation included
Data Logger setup with Data collector Optical
Dimensions: 78 x 55 x 18 mm
Fixed antenna: 60 mm
Battery type: AA x 1
Temperature, humidity, UV. Lux data logger with memory
measurement data for PC via USB port
measurement data for PC via RS232 Port
8,000 measurements per Type in memory with date and time stamp
Luminance: 0 - 130,000lux
UV intensity: 0 - 30mW / cm2
External sensors
Free Cloud Service: TD Webstorage for data collector
LCD Display Displays current measurements
PC Software: Tools and presentation included
Dim: 78 x 55 x 18 mm
Battery type: AA X 1
1-wire lysmåler til synligt lys
0 - 83.000lux med 1 lux opløsning
Op til 23bit opløsning
Automatisk fuld skala justering
Kan kaskadekoples via RJ11 stik
Forsynes fra Controller med 5VDC/4mA
Maks. 30 meter kabel
Mål: 85 x 35 x 24 mm
IP30 plasthus med flange
Compact environmental meter with e-ink display
CO2 Concentration 0 - 9999 ppm
Temperature 0 - + 50 ° C
Relative humidity 0 - 85%
atmospheric pressure 300 - 1100 hpa < Br> Bluetooth (Via App) or Radio (Via Air-Base)
2 AA batteries up to 3.9 years (10 minute intervals)
Dimensions 70 x 70 x 24 mm
small, portable and easy Using
control air quality to reduce Covid-19 infections
Energy meter Per outlet in KWh.
Cannot turn on / off exits !!
8 x 230vac IEC C13 Outlet with energy measurement in kWh per removal.
Web interface
Measuring module for analog in / out and digital in / out
16 x analog inputs 16 bit, (± 10V, ± 5V, ± 2V, ± 1V)
2 x analog outputs 16 bit, (± 10V )
32 x digital inputs / outputs Choose with SW
Total Sample Rate 250khz
Galvanically Isolated for LAN
Digital Inputs / Outputs are TTL / CMOS <3 x Counter 32 Bit, Max. 16 MHz
pulse, increment decoder or pulse measurement
TCP / IP Ethernet
power supply from PoE or externally with 12-40VDC
synchronized for real-time
comes with programming examples in VB, C++ Delphi ,. Net
Can be used with NextView, LabVIEW and Profilab Graphic
14 days free trial with NEXTVIEW 4
The 16-bit A / D converter in data logger failed
With cold-junction temperature compensation to 8 Megabyte memory to log data
USB and RS232, automatic baud rate up to 115.2kbit
Battery operation - 12 years battery
, if you acquire: Software for configuration export, plotting, analysis and reporting (not included)
Configurable alarm controls
measurement speed from 20 milliseconds (1 channel) to 12 hours
Robust aluminum housing
coated PCB for protection against moisture, corrosion
Dimensions: 88 x 65 x 24mm
Weight: 200 grams
USB Temperature logs incl. Software
Operating temperature: -35 To + 80 ° C
USB interface for set-up and data Download
2 Programmable / custom alarms
IP67
Windows from XP up to 10 (32 and 64 -Bit).
The 16-bit analog-to-digital converter
Versions: 0-20VDC, 0-10VDC, 0-5Vdc, 0-2VDC
With temperature compensation
4 Megabytes of memory to log data
USB and RS232, automatic baud rate up to 115.2kbit
Programmable input ranges (0-2 VDC, 0-20 VDC)
Battery operation - 10 year battery
Acc: Software for configuring, downloading, graphing, analysis and alarm reporting (supplied)
onfigurable controls alarm / surge control
Measurement speed of from 20 milliseconds (channel 1) to 12 hours
Robust aluminum housing
coated printed circuit board for protection against moisture, corrosion
16-bit analogue-to-digital converter
With temperature compensation
4 Megabyte memory to log data
USB and RS232, automatic baud rate up to 115.2kbit
Programmable input ranges (0-2 VDC to 0-20 VDC)
Battery operation - 10 year battery
Acc: Software for configuring, downloading, graphing, analysis and alarm reporting (not included)
Configurable alarm controls / overvoltage control
Measurement speed from 20 milliseconds (1 channel) to 12 hours
Robust aluminum housing
coated printed circuit board for protection against moisture, corrosion
RS485 / RS422 / RS232 converter for Meter-Bus meters, actuators, etc.
Supports up to 100 Meter-Bus meters (slaves)
Selecting the serial port, only one can be selected to be active
2 x Baud rate (M-bus and COM port can be selected at different speeds)
Baud rate: 300 to 115,200 bps
Transparant data - no protocol conversion
M-bus connection is 2-wire , max. 350meter.
larger distance up to 5km requires a number of M-bus repeaters
Supply voltage: 10 - 30VDC, 1.8 - 12Watt
Dimensions: 122 x 72 x 33 mm | Removable terminal blocks
Operating temperature: -25 - + 75 ° C
DIN bracket
Robust plastic housing
Web based controller with 8 digital inputs
Digital High is: +4 - +26VDC
8 x digital inputs Opto-isolated
Common ground
200Hz Counter - 24bit
Tasks: 50 Schedule Planned, 50 Conditional, 20 Tuffer Terms
Email Alarms by defined conditions
Supports encrypted e-mail servers such as Gmail
RTC with NTP server synchronization
No software required
Graph (Logged data)
HTTPS / TLS encrypted
Static or DHCP IP Address configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC
Dim: 98 x 78 x 36 mm
Connect up to 12 "AIR" sensors (optional 100 "AIR" sensors)
Independent local data storage or Cloud
E-mail alert (requires network connection)
SMS alert ( requires supported USB modem)
Measurement data for up to 10 years with 100 sensors
Mesurment intervals: 1, 2, 5, 10 minutes
Power voltage: 12VDC
Operaiting tempeture: 0 °C to 40 °C