Item number ETH4SER-K

4 Ports serial port server, RS232 / 422/485. Serial Device Server. Jetport 5604.

Spare part

External COM ports via Ethernet and Internet

Serial Device Server with 4 x RS232, RS422 or RS485

527.56 €
Excl. VAT
Quantity
Physically in stock
file_download DOWNLOADS

Specifications

Administration Indstilles over netværket via krypteret http (https) vha. enten SSH konsol eller JetPort Commander Windowsprogram
Operating Temp. -10- +70°C
Andet Alarmering via e-mail ved fejl. 16 IP-adresser kan gemmes i en ”adgangsliste”. Leveres inkl. 100 ~ 240 VAC adapter, program CD og manualer
Kabinet Metalkabinet i format 46,5 x 145 x 120 mm (H x B x D)
Montering DIN skinne monteringsdele, vægbeslag
Netværk 2 x 10/100 Mbit Ethernet redundant netværksport, auto fallback mindre end 200 ms
Porte Fire porte, der kan bruges som RS232, RS422 eller RS485. Hastigheder fra 110 til 460 Kbit/s, Databit:5/6/7/8, Stopbit:1/1,5/2. Paritet: Lige/Ulige/Ingen
Protokol TCP, UDP, Telnet, DHCP, ICMP, https, SSH, BootP, ARP, DNS, SNMP
Signaler RS232: TxD, RxD, RTS,CTS, DTR, DSR, DCD, GND. RS422: TxD+, TxD-, RxD+, RxD-, GND. RS485 2-leder: Data+, Data-, GND. RS485 4-leder: TxD+, TxD-, RxD+, RxD-, GND
Software COM-driver til Windows NT, 2000, XP, 2003, Vista og Windows 7 32 bit
Stik Serielle porte: 4 x DB9 hanstik. Ethernet: 2 x RJ45 hunstik. Digitale indgange: 4 x dobbelt terminalblok (5 VDC TTL, 0: 0~0.8 VDC, 1: 2~5 VDC). Digitale udgange: 2 x dobbelt terminalblok (5 VDC TTL, 0: 0~0.8 VDC, 1: 2~5 VDC)
Strømforsyning Redundant spændingsforsyning: 12 ~ 48 VDC via 2 skrueterminaler eller 9 ~ 30 VDC via 5.5 mm jack (hun) strømstik

EOL

Newest generation 4-port serial port server with redundant network port and large temperature range. The redundant network port ensures the network connection in error and cable break, with a shift time from port to port of 200 ms. With built-in protocols for secure network traffic (HTTPS and SSH), the data traffic over the Internet will be encrypted. Eth4ser-K is a serial port converter for Ethernet network, for example. Local network and / or Internet.

The double network port with auto Fallback continues to ensure operation of less than 200 ms if one of the network connections fails. The serial ports are set as RS232, RS422 or RS485 with speed up to 460 Kbit / s. The ports can each be set up in different ways; eg. Can serial port 1 set to virtual COM mode, serial port 2 for TCP server, serial port 3 for TCP client and serial port 4 for UPD mode.

The box also has 4 digital inputs and 2 digital outputs - TTL