Item number IND9602

Weighing Indicator GST-9602, 10,000 Display Resolution, 12 VDC Load Cell Excitation, Panel Mount

Load cell excitation: 12VDC +/-5%
Up to 8 x 350 ohm load cells
A/D resolution: 100,000 counts
Display resolution: 10,000
A/D conversion rate: 70 times/sec
Input sensitivity: 0.6-120 uV/D
Non-linearity: 0.01% of full scale
Full digital span calibration
Operating temp: -5 to +40C
Weight approx. 4.0 kg
Power: 100/110/220/240V, 50/60 Hz
250 x 210 x 131 mm

402.00 €
Excl. VAT
Quantity
Physically in stock
file_download DOWNLOADS

Specifications

Operating Temp. -5°C to +40°C
Indgangsimpedans 10 MΩ
Luftfugtighed Max. 95% RH (non-condensing)
Montering Panelmontering
Strømforsyning 100, 110, 220 or 240 VAC, 50/60 Hz (factory set)
Weight Approx. 4.0 kg
Dimensioner 250 x 210 x 131 mm (W x D x H)
Temperature Coefficient Zero: ±(0.2 µV ±0.0008% of initial offset voltage)/°C; span: ±5 ppm/°C of reading
Excitation Voltage 12 VDC ±5% (load cell excitation)
Model GST-9602
Number of load cells Max. 8 load cells of 350 Ω each (load current max. 80 mA)
Input sensitivity 0.6 µV/D to 120 µV/D
Zero adjustment 0.35 mV to 24 mV
Span adjustment Full digital calibration
Display resolution 10,000 divisions
A/D resolution 100,000 counts
A/D conversion rate 70 times/sec.
A/D conversion method 3-phase tare, integrating dual-slope
Under-zero indication Displays "---"
Non-linearity +0.01% of full scale
Panel cutout 232 (+1.0/-0) x 121 (+0.8) mm (W x H)

Panel-Mount Load Cell Indicator for Weighing Systems

This panel-mount digital load cell indicator reads and displays the signal from strain-gauge load cells in weighing and force measurement systems. It suits system integrators who need a stable, accurate readout built into a control panel or machine front.

Powers Up to Eight Load Cells

The built-in 12 VDC excitation supply can drive up to eight 350 ohm load cells, with a maximum load current of 80 mA. This allows multi-cell platforms, tanks and hoppers to be connected to one indicator without an external excitation supply. The input sensitivity range of 0.6 to 120 uV per display division covers both low-output and high-output cells.

Fast, Fine-Resolution Signal Conversion

The dual-slope integrating A/D converter resolves 100,000 counts and updates 70 times per second, so the display follows load changes closely. The display resolution is 10,000, and non-linearity is within 0.01% of full scale. Calibration is fully digital, so no potentiometers need to be adjusted, and the wide zero adjustment range compensates for the dead load of a hopper or platform.

Panel Installation and Mains Supply

The indicator mounts in a standard panel cutout. The mains voltage (100, 110, 220 or 240 V AC, 50/60 Hz) is set at the factory, so specify it when ordering.