Item number VTL591
Analog Water Leak Sensor for Leak Detection Cable, 2-Wire, 100 m Max Distance, -10 to +80°C
Indoor water leak cable monitor
Analog leak sensor
Detects resistance drop in leak cable
Connects to any analog port
Interface: 2-wire WLC to RJ
Max distance 100 m
Requires WLC leak cable (option)
Operating humidity 5 to 95%
Operating temp -10 to +80C
Power 60 mW
9 x 15 x 3.7 mm (W x D x H)
Weight 0.14 kg
62.31 €
Excl. VAT
Quantity
On the way in
Specifications
| Operating Temp. | -10°C to +80°C |
|---|---|
| Anvendelse | Indoor leak detection |
| Interface | 2-wire leak cable to RJ |
| Luftfugtighed | 5 to 95% |
| Rækkevidde | Max. distance 100 m |
| Strømforbrug | 60 mW |
| Tilbehør | Requires a separate leak detection cable, available in various lengths |
| Weight | 0.14 kg |
| Dimensioner | 9 x 15 x 3.7 mm (W x D x H) |
| Measuring Parameters | Water/moisture - detects a drop in resistance in the connected leak cable |
| Input Type | Analog sensor connected to an analog port on the monitoring unit or expansion unit |
Indoor Water Leak Sensor for Leak Detection Cable
The VT591 is an analog water leak sensor for indoor monitoring, intended for system integrators who add leak detection to an existing monitoring setup. It reacts to a drop in resistance in a connected leak detection cable, so a single sensor can cover a whole cable run instead of one spot.
Works with a Separate Leak Detection Cable
The sensor does not detect water on its own. It needs a WLC leak detection cable, available in lengths of 3, 6, 10, 15 or 25 m (WLC3, WLC6, WLC10, WLC15, WLC25). This lets you match the cable length to the area you need to protect, such as the floor along a rack row or around cooling equipment.
Connects to Any Analog Port
The sensor plugs into any analog port on the monitoring unit or on the VT408 expansion unit. It can be placed up to 100 m from the unit, so it can be installed near the monitored area rather than next to the monitor.
Other products in the same category:
Indoor temperature sensor
Compact indoor temperature analog sensor
Connects to Vutlan monitoring devices
Optimal Temperature range: -10°C to +80°C
Accuracy: ±0.15 °C at room temperature
Cable length: 3m
Max length from controller: 100m
Connection: RJ-11 / 6P4C
Dimensions: 60×18×18 mm
Weight: 70g
Power consumption: 60 mW
Package includes: Sensor, cable, screw, sticker
40.87 €
Item number:VTL100047
AC Current Transducer 50-500A, 0-5VDC Output, Open-Loop, -10°C to +80°C
AC current transducer, open-loop
Measures AC current 50-500A
Output 0-5VDC
Requires VT405 Hall current converter
RJ-11 / RJ-12 connection
Max distance 50 m
Operating humidity 5 to 95%
Operating temp -10 to +80C
Power: 100 mW
11 x 14 x 6.5 mm (W x D x H)
Weight 0.19 kg
Call +45 56 66 20 20 for price
Item number:VTLAC0-100A