Item number CHANN-RTD-THERM-ANALO
8-Channel RTD/Thermistor Analog Input Module with RS-485, DCON
8 x RTD/Thermistor Input Channels
Supports Pt100, Pt1000, Ni, Cu RTDs
16-bit Resolution, +/-0.05% Accuracy
RS-485 Port, DCON Protocol
Baud Rate 1200-115200 bps
3000VDC Intra-module Isolation
Overvoltage Protection +/-120VDC
Consumption 0.6W Max
-25~75C (special components required)
31 x 134 x 144 mm
Watchdog Timer (Module & Comm)
345.72 €
Excl. VAT
Quantity
On the way in
Specifications
| Resolution | 16-bit |
|---|---|
| Bandwidth | 15.7 Hz |
| Watchdog Timer | Yes, Module (1.6 Seconds), Communication (Programmable) |
| Status | 1 x Power and Communication16 x High/Low Alarm Signals |
| Intra-module Isolation | 3000 VDC |
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal±8 kV Air for Random Point |
| Channels | 8 |
| Accuracy | ±0.05 % of FSR |
| Sampling Rate | 12 Hz (Total) |
| RS Immunity (IEC 61000-4-3) | 3 V/m, 80 MHz ~ 1 GHz |
| Sensor Type | Pt100, Pt1000, Ni100, Ni120, Cu50, Cu100, Cu1000 |
| Resistance Measurement | 3.2 kΩ |
Analog Sensor Input Module
This analog sensor input module is designed to interface with a wide range of RTD and thermistor sensors in industrial monitoring systems. It converts analog resistance signals into digital data for reliable temperature measurement in demanding environments. The module is ideal for integrators who need precise, isolated temperature readings across multiple channels.
8 Channels · 16-bit Resolution · RS-485 with DCON Protocol · -25 to +75°C Operation
Key Features and Benefits
- Multiple Sensor Support - compatible with Pt100, Pt1000, Ni100, Ni120, Cu50, Cu100 and Cu1000 sensors
- High Accuracy - 16-bit resolution with +/-0.05% of FSR accuracy for reliable readings
- Individual Channel Configuration - each channel can be set independently for its sensor type
- Open Wire Detection - identifies broken sensor connections to prevent faulty readings
- Built-in Watchdog Timer - monitors module and communication status for improved reliability
Typical Applications
The module suits industrial and building automation systems that require accurate, isolated temperature monitoring across several sensors.
- Industrial temperature monitoring
- Process automation systems
- Building automation systems
- Remote RTD monitoring stations
A robust and precise solution for multi-channel RTD temperature measurement in industrial networks.
Other products in the same category:
Extension module for L-CON-LOG-x series. 6 relay outputs (normally open, COM N.O.) 5 Digital inputs.
Built-in module with screw terminals
5 x digital inputs, Wet Sink / source. 0 - + 50VDC
All inputs are with 32bit counter
2 x relay outputs 30VDC / 2A to 4 x 35 VDC relay outputs 6A, 6A
Relays 250VAC is non-inductive load
195.91 €
Item number:L-CON-LOG-D5I6R+
Expansion module for L-CON-LOG-x series. 8 digital inputs, Wet, 0 - + 50VDC, 8 x Digital outputs (OC) + 50VDC 700mA
The integration module with screw terminal
8 x digital inputs 0 - + 50VDC
All inputs with 32 bit counter (50 Hz)
8 x digital outputs, the Open Collector + 50VDC 700mA / channel
127.03 €
Item number:L-CON-LOG-D8I+