Item number ETHER-DIGIT-MODUL-16-2

Ethernet Digital I/O Module, 16 x Isolated Open Collector Output, Modbus TCP/UDP

16 x Isolated Open Collector Output
Sink Type, 100mA/channel at 25C
Load Voltage +5 ~ +30VDC
Modbus TCP, Modbus UDP
1 x RJ-45 10/100 Base-TX
Built-in Web Server
Programmable Watchdog Timer
2-way Isolation, Ethernet 1500VDC, I/O 2500VDC
ID, Password and IP Filter Access Control
10 ~ 30VDC
-40 ~ +75C (special components required)
72 x 123 x 35 mm

259.96 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

Installation DIN-Rail Mounting
Type Isolated Open Collector
Operating Temperature 40 ~ +75°C
Watchdog Timer Module, Communication (Programmable)
Status Run, Ethernet
Ports 1 x RJ-45, 10/100 Base-TX
Consumption 2.7 W (max.)
Dimensions (mm) 72 x 123 x 35 (W x L x H)
Storage Temperature 30 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
Reverse Polarity Protection Yes
ESD (IEC 61000-4-2) ±4 kV Contact for each terminal ±8 kV Air for random point
Channels 16
Safe Value Programmable
Powered from Terminal Block +10 ~ +30 VDC
Sink/Source (NPN/PNP) Sink
Load Voltage +5 ~ +30 VDC
Load Current 100 mA/channel at 25°CDirect Drive Power Relay Module
Power on Value Programmable
Protocol Modbus TCP, Modbus UDP
2-way Isolation Ethernet: 1500 VDCI/O: 2500 VDC
EFT (IEC 61000-4-4) ±4 kV for Power Line
Surge (IEC 61000-4-5) ±0.5 kV for Power Line
Access Control ID, Password and IP Filter
Built-in Web Server Yes

Digital I/O Module

This digital I/O module provides 16 isolated open collector output channels for controlling external devices over Ethernet. It is well suited for industrial automation applications requiring reliable and isolated digital control.


16 x Isolated Open Collector Output · Modbus TCP/UDP · 2-way Isolation · -40 to +75°C


Features that make the difference

  • 16 isolated output channels - enables flexible control of multiple external devices
  • Modbus TCP/UDP protocol - easy integration into existing SCADA/PLC systems
  • 2-way isolation - protects against noise and voltage differences between Ethernet and I/O
  • Programmable watchdog timer - ensures stable operation with automatic recovery on failure
  • Built-in web server - allows easy configuration and monitoring directly in the browser


Application areas

The module is suitable for industrial environments requiring robust digital output control with Ethernet connectivity.

  • Automated production control
  • Remote control of relays and actuators
  • Monitoring of industrial processes
  • Integration into SCADA and PLC systems


With robust isolation, a wide operating temperature range and Modbus support, this module is the right choice for demanding industrial I/O tasks.