Item number EXPAN-CONTR-SLOT-MODBU

I/O Expansion Controller 4-Slot with Modbus TCP/RTU Gateway, -25~75°C

4 x I/O expansion slots (I-8K/I-87K)
80186 16-bit CPU, 80 MHz
2 x RJ-45 10/100 Modbus TCP
Modbus TCP to RTU Gateway
2 x RS-232, 1 x RS-485 isolated
1 x RS-232/RS-485 combo port
microSD slot up to 32GB
5-digit 7-segment LED display
MiniOS7 operating system
10-30VDC, 6.7W
231 x 132 x 111 mm
-25~75°C (special components required)

700.82 €
Excl. VAT
Quantity
On the way in
file_download DOWNLOADS

Specifications

CPU 80186 or compatible, 16-bit and 80 MHz
DIP Switch 8-bit for address
Flash 512 KB
Installation DIN-Rail, Wall mounting
Type 5 x Digit 7 Segment LED Display
Operating Temperature -25 ~ +75 °C
OS MiniOS7
Real Time Clock Provide seconds, minutes, hours, dates, day of week, month, year
Watchdog Timer Yes
Status 1 x Run, 1 x Module offline, 1 x WDT, 1 x Power
Buzzer Yes
Ports 2 x RS-232, 1 x RS-485 (3000 VDC Isolated), 1 x RS-232/RS-4852 x RJ-45, 10/100 Base-TX
Input Range +10 ~ 30 VDC (1 kV Isolated )
Redundant Power Inputs Yes
Consumption 6.7 W
Dimensions (mm) 231 x 132 x 111 (W x L x H)
Storage Temperature -30 ~ +80 °C
Humidity 10 ~ 90 % RH, Non-condensing
I/O Type I-8K, I-87K series
Slots 4
Protocol Modbus TCP Slave, Modbus TCP to RTU GatewayModbus RTU/ASCII Slave
Development C Language
EEPROM 16 KB
NVRAM 31 Bytes
SRAM 768 KB SRAM, 512 KB Dual battery backup SRAM
Storage Expansion 1 x microSD card slot, supports up to 32 GB
Push Button 4

I/O Expansion Controller

This I/O expansion controller is a rugged industrial device designed to manage remote I/O modules over Ethernet and serial networks. It acts as a Modbus TCP slave and gateway, bridging Modbus TCP and RTU/ASCII networks for distributed automation systems.


4 Expansion Slots · Dual Ethernet (10/100) · Modbus TCP/RTU Gateway · -25 to 75°C Operation


Key Features

  • 4 I/O Expansion Slots - supports I-8K and I-87K series modules for flexible I/O configuration
  • Modbus TCP to RTU Gateway - bridges Ethernet and serial Modbus networks seamlessly
  • Redundant Power Inputs - increases system uptime and reliability
  • Wide Operating Temperature - operates reliably from -25 to 75°C in harsh environments
  • microSD Storage - supports up to 32GB for data logging and configuration storage


Typical Applications

The controller is suited for industrial automation environments where distributed I/O and remote monitoring are required.

  • Factory automation and process control
  • Remote monitoring and data acquisition
  • Building and infrastructure management
  • Distributed control systems with mixed protocols


A reliable choice for connecting Modbus TCP and RTU networks in demanding industrial settings.