LoRa / LoRaWAN

LoRa and LoRaWAN – capabilities and limitations

LoRa is designed to transmit small amounts of data over long distances with low power consumption. This makes it well suited to sensors, meters and data logging, where devices need to send short messages and may need to operate on batteries for long periods.

LoRa is the radio technology itself. LoRaWAN is the network protocol used in many sensor installations to connect devices to a gateway and, through it, to a data system. The explanation below focuses on typical LoRaWAN installations.

How much data can you transmit?

LoRa prioritises range and low power consumption. Its data rate is therefore significantly lower than that of technologies such as Wi-Fi and mobile networks.

With common European LoRa settings using a bandwidth of 125 kHz, the approximate radio data rates are:

Radio settingApproximate data rate SF75470 bit/s, SF97 760 bit/s, SF12250 bit/s

SF stands for Spreading Factor. A higher SF allows weaker signals to be received, but transmissions take longer. The same message therefore uses more airtime when the connection requires a slower setting. These figures describe radio data rates. The effective throughput for the customer's data is lower because of protocol overhead and restrictions on transmission time.

Message sizes are also limited. At slower European settings, a LoRaWAN message may, for example, carry around 51 bytes of application data. At faster settings, it may carry more than 200 bytes, depending on the configuration. Temperature, humidity, soil moisture and battery status can normally be packed into a very short message.

For this reason, LoRa is not a practical solution for video transmission, conventional voice calls, large files or continuous data streams. These applications require much greater capacity and more continuous access to the connection.

Limited transmission time – duty cycle

A device cannot necessarily transmit again immediately.

In the European 868 MHz band, many LoRaWAN installations use frequency sub-bands with a 1% duty cycle limit. This means a transmitter may spend no more than 1% of its time transmitting in the relevant sub-band – equivalent to 36 seconds of airtime over one hour. Other sub-bands and channel access methods may have different limits.

As a simple calculation: if a message takes one second to transmit, evenly spreading transmissions under a 1% limit corresponds to a pause of approximately 99 seconds afterwards. The actual implementation depends on the equipment and configuration. The limit does not necessarily apply separately to each channel. Several channels may share the same sub-band and therefore the same airtime allowance.

Why can a reply or command be delayed?

There is a difference between a sensor sending a measurement and the system sending a message back to that sensor.

A typical battery-powered LoRaWAN Class A device spends most of its time asleep. After transmitting, it opens two short receive windows, RX1 and RX2, during which it can receive a message from the network. If the message cannot be delivered then, the network must wait until the device has made a later transmission.

If a sensor transmits every 15 minutes, for example, a command sent to it may have to wait almost 15 minutes for the next receive opportunity – and longer if the transmission or reply is lost. This does not mean every measurement takes 15 minutes to arrive. The waiting time mainly arises when trying to contact a sleeping device.

Standard LoRaWAN does not normally request permission first and receive an assigned transmission slot. The device initiates its own transmission within the constraints of the protocol and radio regulations. Class B provides scheduled receive opportunities called ping slots. Class C listens almost continuously and can therefore receive messages sooner, but consumes more power.

Some LoRa systems also check the channel before transmitting. This is called Listen Before Talk, and Channel Activity Detection (CAD) can be used to detect LoRa activity. This checks channel activity; it does not, by itself, reserve a time slot.

A greenhouse is a good example

In a greenhouse, sensors can measure temperature, humidity and soil moisture and send a short summary every few minutes. It is often more useful to observe trends over hours and days than to receive every individual measurement immediately.

A sensor can also take measurements more frequently locally and, for example, transmit the minimum, maximum and average every five minutes. This reduces the amount of data while retaining useful information about conditions. The actual transmission interval must be adapted to coverage, radio settings, the number of sensors and network constraints.

LoRaWAN is therefore well suited to:

  • Periodic logging of temperature, humidity and other environmental data.
  • Meter readings and short status messages.
  • Occasional position reports.
  • Notifications of abnormal conditions where some delay is acceptable.

If ventilation or irrigation must respond quickly and predictably, the necessary control should operate locally. LoRaWAN can still be used for monitoring, historical records and changing settings where delivery time is less critical.

LoRa is particularly useful when the task is to collect a small number of useful measurements from many locations with low power consumption. If the application requires video, large amounts of data or a guaranteed fast response, the connection must be selected to meet those requirements.

LoRa / LoRaWAN
There are 8 products.
Outdoor industrial LoRa Node controls used for data collection from multiple sensors

LoRaWan transceiver with 2 x digital inputs
LoRaWan transceiver with 2 x analog inputs 4-20mA / 0-10V
LoRaWan transceiver with relay output (SPDT)
Supports LoRa Class C protocol
Serial port: RS232 or RS485 (Transparent data)
Collect data sent to Lora-Gateway Controller
Frequency: 868MHz - Range Up to 10 km
Configuration Port: Micro USB
Operating temperature: -40 - +70°C
Supply voltage: 5 - 24VDC
Dim: 120 x 120 x 56 mm

3,333.00 kr
Item numberLORA-NODE-W-CNTR
On the way in
LoRaWAN gateway i industriel kvalitet med pålidelig forbindelse til IoT. Indbygget 5 ports switch

LoRaWan with stable connection to IoT units
4 x 10/100 / 1000Base-T RJ45 LAN ports
1 x 10/100 / 1000Base-T RJ45 WAN port
1 x LoRa antenna - 2DBI with SMA male
1 x Serial console Port (RS485)
2 x DI / DO and 1 serial port (RS485) for Modbus applications
For EU 868MHz (SUB 1G) Frequency
8 Programmable parallel demodulation paths
static IP / PPPoE / DHCP client for WAN
DHCP server / NTP client for LAN
Protocols: TCP / IP, UDP, ARP, IPv4, IPv6
port forwarding; Qos; DMZ; IGMP; UPnP; SNMPv1, V2C, V3
Dim: 135 x 135 x 50 mm

9,724.00 kr
Item numberLORA-GATEWAY5
On the way in
LoRaWan gateway in industrial quality with to IoT units. Dual band wifi. Built in 5 Ports Switch

LoRaWan with stable connection to IoT units
Dual Band WiFi - 2 antennas with RSMA male
3 x 10/100/1000Base-T RJ45 LAN ports
1 x 10/100/1000Base-T RJ45 Wan-Port
1 x LoRa Antenne - 2DBI with SMA male
2 x DI / DO and 1 serial port (RS485) for Modbus applications
to EU 868MHz (SUB 1G) Frequency
8 Programmable Parallel Demodulation Roads
Static IP / PPPoE / DHCP Client for WAN
DHCP Server / NTP Client for LAN
Protocols: TCP / IP, UDP, ARP, IPv4, IPv6
port forwarding; Qos; DMZ; IGMP; UPnP; SNMPv1, V2C, V3
Dim: 135 x 135 x 50 mm

10,683.00 kr
Item numberLORA-GATEWAY5-WIFI
On the way in
LoRa Gateway, RS485, Modbus, 1 Analog Input, 1 Digital I/O

Outdoor gateway set of 2 devices

1x Master, 1xSlave (transparent RS-485 transmission)

Protocol LoRa (not LoRaWAN)

Frequency range 410–525 MHz / 862–1020 MHz (depending on local regulation)

Sensitivity Up to –136 dBm @ SF=7 / 10.4 kHz bandwidth

RF power Max. 2 W

Interface RS-485 × Digital Input × 1 / Digital Output × 1

Serial Baud Rate 1200–230 400 bps

Encryption AES-128 / AES-256

Digital Input High/Low signal rating

Digital Output PWM / Latch mode

Topology types Broadcast / Group / Peer-to-Peer

Material Flame retardant

Dimensions 10 × 10 × 4.8 cm (without antenna and external connections)

Weight 2x 195 g

IP rating IP68

Operating temperature –40°C to 85°C

Input supply 12–36 V DC / 1 A

Output supply 5 V DC / 200 mA

Power consumption Receiving: 24 V 15 mA @868/920 MHz, Sending: 24 V 400 mA @868/920 MHz (2 W)

With set of RS-485 Modbus RTU communication

5,534.00 kr
Item numberLORA-RS485-DIO
On the way in
Wireless Transmission for RS232/RS485 up to 20km via LORA network

LoRa Wireless Transmission with RS232 & RS485

Baud rate: 1200~115200

DB9 for RS232 / screw terminal for RS485

5W Power Output for strong signal

Frequency Range: 433MHz

Long-range up to 20km MAX connectivity

Three-proof Coating: Anti-Fungal, Anti-Humidity, Anti-Salt Spray

Weight: 240±5g

Operation temperature range: -40℃~+85℃

Power input: 8~ 28V DC

Transparent RS232/RS485 Interface

2,660.00 kr
Item numberLORA-RS485-RS232
Physically in stock
Wireless transmission to RS232/RS485 up to 10 km via LORA network

Wireless LoRa transmission with RS232 and RS485

Baud rate: 1200~115200

DB9 to RS232 / screw terminal to RS485

Antenna connector: SMA female

1W power output for strong signal (30dBm)

Frequency range: 868 MHz

Long range of up to 8 km MAX connection

Three-resistant coating: Antifungal, moisture-proof, salt spray

Weight: 240 ± 5g

Operating temperature range: -40℃~+85℃

Power input: 8~28V DC

Transparent RS232/RS485 interface

2,660.00 kr
Item numberLORA-RS485-RS232-868
On the way in
LoRaWAN to Modbus TCP Master Converter 868 MHz

LoRaWAN / Modbus TCP Master - Converter 868 MHz

1 x RJ45 Ethernet port

1 x SMA Female Antenna port

Modbus TCP Master protocol

LoRaWAN 868 MHz antenna protocol

100 Base-T Autosensing Ethernet

Programmable LoRaWAN data rates

Power: 15-21V AC or 18-35V DC

2-way 5mm terminal block power

-40C to +85C

DIN Rail mount

71 x 60 x 95 mm, approx 200g

Call +45 56 66 20 20 for price
Item numberLORA-MODBUSTCP
On the way in
Long-Range Industrial LoRa Gateway with transparent I/O & MODBUS

Long-range wireless LoRa communication (non-LoRaWAN)

RS-485 MODBUS RTU protocol

1x analog input 0–10V / 0–20mA / 4–20mA / ADC (0–10V)

1x analog output synchronization function

1x Digital input High/low signal detection

1x digital output supports PWM/Latch mode

AES-128/256 encrypted transmission

Rugged IP68-rated waterproof housing

Wide operating temperature range of -40°C to 85°C

Ideal for industrial, agricultural and environmental IoT

Low power consumption for remote or battery-powered deployments

Set of 1x Master, 1x Slave

Non-transparent RS-485 transmission!

5,723.00 kr
Item numberLORA-RS485-AIO
On the way in
Showing 1-8 of 8 item(s)